Maintenance Instructions
Currency Singularity
4-28
NCR 5635 Spray Currency Dispenser Service Manual
NCR - CONFIDENTIAL AND PROPRIETARY
Use pursuant to Company Instructions
Calibrating the
Dispenser
4
Proceed as follows to calibrate the dispenser:
1
Power on the dispenser.
2
Load the cassette with the test currency and insert it into the top
pick position.
3
Use the Set Bill Sizes command to enter the size (width in
millimetres) of the test currency.
4
Use the Set Bill Singularities command to enter the singularity
of the test currency.
5
Use the Multi-Cassette Dispense command to dispense around
2000 items of the test currency.
The above procedure has adjusted the internal LVDT compensation
factor around 8 times which allows for individual LVDT gain. The
dispenser can now be considered to be calibrated and can be used to
evaluate the currency to be dispensed as described in the next
section.