5
Initial Testing
Step 9:
(This will only work if the module was configured for UDP broadcast or if this
is done on the computer specified as the server IP). For testing purposes open Base
Station once more on a windows computer connected to the same network as the PN
controller. Click the More button in the upper right corner of the select connection
window. Click the Com Operator button which appears below. When asked to
register you can specify register later. Click the Chain icon button in the upper left
corner of Com operator to open a new connection. If you set the module up for UDP
broadcast click the UDP tab, enter the port number specified as the notification port in
the WiFi module in the Listen Port box, then click OK. If you setup the module for a
TCP socket connection click the TCP Server tab and enter the port number specified
during setup as the server port number is the Listen port box and click ok. You will
now see a send/receive window. Trip and input on the controller using a dry contact
and you should see data received in Com operator. This concludes the setup of your
controller.