NAVIOR-24S
™
Appendix D
NMEA 0183 Communication Interface
200
NAVIOR-24S ™
Revision
V1.00 20.05.2008
POPPS – Time label control
This message contains information about time mark settings in the receiver. It makes possible to
show current settings and apply new time mark settings into receiver.
Format:
$POPPS, L, I, T, CF, xxx, r1, r2<CR><LF>
Field
Format
L
type of time label (P=software)
I
time label mode (S=second)
T
aligned time scale (G=GLONASS, N=GPS, U=UTC, S=UTS SU)
CF
indicator of time label correction (0=no corrected, if no zero value = ±2ms)
xxx
time label duration in microseconds (max allowed value is 1600)
r1 reserved
field
r2 reserved
field
<CR><LF>
2 ASCII control characters
This message is used to review current settings of time label in the receiver. It also can sets new
parameters of time label into receiver. When new parameters sets into receiver, it confirm
parameters setting by single responsible message with new parameters.