NAVIOR-24S
™
Appendix B
Navis Standard Interface Protocol BINR
118
NAVIOR-24S ™
Revision
V1.00 20.05.2008
Internal statistic
Set/Request Packet 30h
Packet sets the parameters of the internal statistics.
1 00 – disable the packet 44h transmission
FF – transmission temp (from 01 to 255 in hexadecimal system)
Data type format – INT8U
2 00 - disable internal statistic01 – enable internal statistic
Data type format - INT8U
3 00 - use previous data of statistical processing
01- – clear previous results and start statistic processing from the beginning
Data type format - INT8U
4 n (from 01 to 255) - set interval of PVT using in the statistical processing (in seconds)
Data type format - INT8U