13
English
4
In the Parameter information time mode, use the Up (+) or Down
(-) buttons to select “P.18”. Then, press the Info button to enter the
NaviLink connection setting mode.
5
In the NaviLink connection setting mode, use the Up (+) or Down (-)
buttons to change the value and press the Info button to set to the
desired mode.
Display
Description
NaviLink connection setting mode
Cascade connection setting mode or
connection setting unavailable
NaviLink connection enabled (ON)
NaviLink connection disabled (OFF)
Verify that the NaviLink connection setting mode is disabled (OFF) for
cascade systems.
Configuring the connection setting mode for NPE
models
Adjusting this setting is required for single NPE units ONLY. Do not adjust
any of the following parameters for cascade systems.
You can configure the NaviLink connection setting mode on the front
panel of NPE water heaters connected to the NaviLink.
1
On the front panel, press the Power button to turn off the water
heater.
2
Enter the R&D information menu by pressing the Up (+) button three
times, the Down (-) button three times, and then the Up (+) button
four more times.
3
Use the Up (+) or Down (-) buttons to move to “2.PAR” (Parameter
information mode), and then press the Info button.
Display
Description
Technical information
Parameter information