INTRODUCTION

DIMENSIONS AND INCLUDED PARTS

    

     

     

          

NOTE:

  Connections to the appliance and neutralizer kit must be installed to ensure that no condensate

  backflow can occur. Connect corrosion resistant piping and secure it to the floor or wall to prevent

  movement and/or damage.

Please follow these installation instructions carefully in order to avoid a safety hazard and/or injury.

WARNING

• “Risk of damage to appliance”.  The neutralizer kit inlet and discharge must be at a lower

   elevation than the condensate drain from appliance.

•  Do 

NOT

 allow exhaust flue gases to vent through the neutralizer kit. All condensate drains

   must have a trap to prevent flue gas leakage. Flue gas leakage can cause injury or death from

   carbon monoxide.

•  Connection to the appliance and neutralizer kit must be installed to ensure that no

   condensate backflow can occur into the appliance.

•  Do not connect more than ONE appliance to the neutralizer kit.

Condensate Neutralizer

Installation Instructions

PREPARE FOR INSTALLATION

FLOW

Condensate Neutralizer Kit Includes:

•  One (1) corrosion-resistant neutralizer housing with 4” fill/access openings (0.26 gallon / 1 liter volume)

   with 3/4”- 14 FNPT threaded INLET and OUTLET connections

•  One (1) 1/2” FNPT x 1/2” PVC Socket Weld Adapter

•  Two (2) 3/4” MNPT x 1/2” PVC Socket Weld Adapters

•  One (1) Wall Mounting Bracket with Screws

OPERATION

•  The appliance condensate will flow through the neutralizing media, raising the pH of the condensate to a level

   that will help prevent corrosion of the domestic drain and the public sewer system.    

SPECIFICATIONS

Condensate Neutralizer Kit Part No.:  

GXXX002212

Replacement Media Part No.:  

GXXX001323

Max Flow Rate:

  1.6 gph (6.05 lph)

Weight:

  4.0 lbs (2.0 +/- 5% kgs)

62mm 

2.43"

128mm

5.03"

60mm 

2.37"

238mm 9

.36"

159mm 6.28"

¾” FNPT Inlet

¾” FNPT outlet

70 mm

3.75" mm

*Required

  bo�om clearance

Wall Bracket

 

          •  

Open the capsule and ensure media is level inside. If necessary, the orientation of the neutralizer can be reversed

              by removing the wall bracket and moving it to the other side of the lid (see Figure 1 on next page).

          •  The INLET has a top connection port and the OUTLET has a side connection. Mount the neutralizer unit on the

             wall by securing it with the provided bracket (see INCLUDED PARTS section above).  