![Navien G 002212 Series Installation Instructions Download Page 1](http://html1.mh-extra.com/html/navien/g-002212-series/g-002212-series_installation-instructions_3561737001.webp)
INTRODUCTION
DIMENSIONS AND INCLUDED PARTS
NOTE:
Connections to the appliance and neutralizer kit must be installed to ensure that no condensate
backflow can occur. Connect corrosion resistant piping and secure it to the floor or wall to prevent
movement and/or damage.
Please follow these installation instructions carefully in order to avoid a safety hazard and/or injury.
WARNING
• “Risk of damage to appliance”. The neutralizer kit inlet and discharge must be at a lower
elevation than the condensate drain from appliance.
• Do
NOT
allow exhaust flue gases to vent through the neutralizer kit. All condensate drains
must have a trap to prevent flue gas leakage. Flue gas leakage can cause injury or death from
carbon monoxide.
• Connection to the appliance and neutralizer kit must be installed to ensure that no
condensate backflow can occur into the appliance.
• Do not connect more than ONE appliance to the neutralizer kit.
Condensate Neutralizer
Installation Instructions
PREPARE FOR INSTALLATION
FLOW
Condensate Neutralizer Kit Includes:
• One (1) corrosion-resistant neutralizer housing with 4” fill/access openings (0.26 gallon / 1 liter volume)
with 3/4”- 14 FNPT threaded INLET and OUTLET connections
• One (1) 1/2” FNPT x 1/2” PVC Socket Weld Adapter
• Two (2) 3/4” MNPT x 1/2” PVC Socket Weld Adapters
• One (1) Wall Mounting Bracket with Screws
OPERATION
• The appliance condensate will flow through the neutralizing media, raising the pH of the condensate to a level
that will help prevent corrosion of the domestic drain and the public sewer system.
SPECIFICATIONS
Condensate Neutralizer Kit Part No.:
GXXX002212
Replacement Media Part No.:
GXXX001323
Max Flow Rate:
1.6 gph (6.05 lph)
Weight:
4.0 lbs (2.0 +/- 5% kgs)
62mm
2.43"
128mm
5.03"
60mm
2.37"
238mm 9
.36"
159mm 6.28"
¾” FNPT Inlet
¾” FNPT outlet
70 mm
3.75" mm
*Required
bo�om clearance
Wall Bracket
•
Open the capsule and ensure media is level inside. If necessary, the orientation of the neutralizer can be reversed
by removing the wall bracket and moving it to the other side of the lid (see Figure 1 on next page).
• The INLET has a top connection port and the OUTLET has a side connection. Mount the neutralizer unit on the
wall by securing it with the provided bracket (see INCLUDED PARTS section above).