Black / Tip / +Ve

Green

/ Earth

Red / Ring / -Ve

LOW BATTERY

INSTALLING or REPLACING THE

BATTERY

A red LED at the centre of the keypad starts to

flash RED when the battery needs replacing.

Also, at each mode change of the

, a low battery tone will be heard. Once

the low battery LED is on,

will

keep on working to its specification for a

couple of hours, but

.

Remove the three hatch cover screws as

shown below. Unclip the battery and replace

it with a 9V alkaline battery. Make the change

within one minute if you want to retain your

memory contents.

Disconnect from the line and press Monitor

button to extinguish the Green (Mode) LED.

Replace the hatch cover ensuring that the line

cord is correctly routed.

Tighten the screws firmly but do not use

excessive force.

DigAlert

350

DigAlert 350

DigAlert

350

you are advised to

replace the battery as soon as possible

It is very important to ensure that

is off when replacing a battery (No

LED lit).

If you do not do this, when the new battery

is fitted, the test-telephone may not restart

correctly.

m

To cure it, disconnect the battery

for at least 2 minutes and short the terminals

together for a few seconds (when battery not

fitted).

Care and repair

Field repair

Line-cord changing

Line-cord storage

Impact

Field repairs are limited to replacing line cords

(with approved types), replacing belt clips,

and replacing batteries.

Attempting any

repair beyond this at field level is liable to

damage the instrument and will invalidate the

manufacturers warranty.

Remove the three hatch cover screws.

Replace the cord by loosening the terminal

screws. Connect a new, standard cord as per

the diagram. Tighten the screws firmly but do

not use excessive force. Make sure the

battery cover locates properly before

securing it with the 3 screws.

Wrap the line cord loosely around the handle

or preferably make a few loops and pass them

through the belt clip.

is highly impact resistant. Even

if dropped from a great height onto concrete

should survive without

permanent damage. In the event that the

gasket seal should bulge out on impact it is

usually possible to gently ease it back into

position with a blunt tool. Do not attempt to

open the case to make a repair nor should any

force be used or the gasket may split. If a

simple local fix is not possible it should be

returned for repair.

As a result of impact the surface may be

scuffed or gouged. Small scuffs may be

removed with fine grit abrasive paper. Any

sharp burrs resulting from impact may be cut

off with a sharp knife. Do not cut into the body

or this will break the water sealing.

Please note that the waterproof seal integrity

can be damaged by a high impact. If in doubt,

please have your unit checked. Use of the

unit while the seals are damaged may

invalidate the warranty.

DigAlert 350

DigAlert 350

Do not open the case.

D350 User Guide part n° 1201-03-2571 issue 2, 10/01, Sheet 1.

Warranty

Warranty covers all defects of manufacture

and materials.

Chesilvale Electronics agrees to remedy

warranty defects free of charge provided that:

the product is returned pre-paid to the

supplier, it is adequately packed and labeled,

all parts are returned and warranty seals (if

fitted) are not broken.

Warranty does not cover: normal wear and

tear, accidental damage, misuse, abuse or

neglect and is voided by any unapproved

modification.

USER GUIDE

Loud Speaker Test Telephone

r a n g e

DigAlert 350

Tempo Europe Ltd.

Unit 3,

Maesglas Industrial Estate,

Newport,

NP20 2NN

U.K.

(

4

+44 (0) 1633-223 552

+44 (0) 1633-223 948

[email protected]

www.tempo.textron.com