Page 1: ...Operator Manual MONISAFE 400A System V01 00 01 2014 10 7 2014 Nautilus Hyosung Inc All Rights Reserved...

Page 2: ...ersion Date Description of Change Chapter 1 V01 00 00 2013 11 08 New Publication All 2 V01 00 01 2014 10 07 Replaced Windows XP with Microsoft Windows Embedded POSReady 2009 2 2014 Nautilus Hyosung Al...

Page 3: ...nt Body 3 1 Opening the Lower Front Body 3 2 Opening the Security Enclosure 3 3 Closing the Security Enclosure 3 4 Switching Power On Off 3 5 Switching the Power On 3 5 Switching the Power Off 3 6 Pow...

Page 4: ...this manual contact the NHA maintenance staff or help desk For contact information see your support email addresses and telephone numbers that are provided separately What is in This Manual This manua...

Page 5: ...dispensed from the dispenser Servicing and maintenance refer to the supervisor operator and technician s tasks performed to keep the TCR operational Screen refers to the text appearing on the customer...

Page 6: ...entary Program 10 H W Hardware 11 I F Interface 12 LCD Liquid Crystal Display 13 OPL Operation Panel for Customers to Operate 14 OSD board On Screen Display Board 15 P S Power Supply 16 PNC Panel Cont...

Page 7: ...erate the equipment Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reaso...

Page 8: ...pment in an area away from any combustible materials The equipment may catch on fire from overheating or short circuit of the power supply unit Disassembly Warnings Do not disassemble or modify the eq...

Page 9: ...014 Nautilus Hyosung Inc All Rights Reserved Related Documents The following documents complement this one Installation Manual Service Manual VDM Manual Error Code Manual Contact your NHA representati...

Page 10: ...ollowing picture shows the front of the MONISAFE400A and its key units The following picture shows the rear of the MONISAFE400A LCD for Customer Operation Stand by Switch For USB Communication For Hos...

Page 11: ...knotes are stored and the upper body where the CE and the power supply are installed The interior and key units are as follows Note DO NOT use the Main Power Switch when you want to turn off the power...

Page 12: ...gabit LAN On Boarded POWER 12V Customer Operation LCD Type 7 Wide TFT LCD 600cd m 2 Input Method Register type Touch Screen USB Type Bill Recycle Machine Interface Type USB 1 1 Main USB 2 0 BC Sutter...

Page 13: ...100 127Vac 10 13 5A 200 240Vac 10 6 5A Frequency 47 63Hz NORMAL 50 60Hz Battery N A Safety Security Specification UL291 Level 1 Safety Locking device Cencon Lock Additional Function Teller Hold Indic...

Page 14: ...ctronics used in the TCR are similar to that of a personal computer with exception of a multiple USB HUB used to communicate with several devices such as a Bill Recycle Machine Basic Specification of...

Page 15: ...unit converts AC power to DC power and provides the voltage to various modules within the system The power supply unit allows the user to turn on off the system enter power failure mode and perform ot...

Page 16: ...ngthens the replenishment or emptying cycles on cash in cash out systems and at the same time the cash holding per system can be reduced Basic Specification of Bill Recycle Machine Automatic Shutter 1...

Page 17: ...each other with the key The security enclosure of the MONISAFE400A can be accessed after you open the lower front door Opening Closing the Upper Front Body Opening the upper front body as follows 1 T...

Page 18: ...l 3 2 2014 Nautilus Hyosung Inc All Rights Reserved Opening the Lower Front Body Close the upper lower front body door as follows 1 Insert the system key in the lower front body 2 Turn the key clockwi...

Page 19: ...he Security Enclosure Open the Security Enclosure as follows 1 Open the lower front body with key 2 Unlock the security door refer to the relevant instructions detailed under Opening Closing The Secur...

Page 20: ...Closing the Security Enclosure Close the Security Enclosure as follows 1 Lock the security door refer to the relevant instructions detailed under Opening Closing The Security Enclosure Security Door f...

Page 21: ...r supply unit converts AC power to DC power and provides the voltage to various modules within the system The power supply unit allows the user to turn on off the system enter power failure mode and p...

Page 22: ...ff the system is as follows 1 Press the power switch at the right side OFF for 1 second 2 The system will be shut down automatically 3 The operating system will shut down then power will turn off WARN...

Page 23: ...or when the battery cable is not connected MAIN S W Supplies or stops AC power Switch Status Main S W is pressed on I position AC power is being supplied to the power supply unit and only AC IN LED is...

Page 24: ...re which requires a Smart Key is not available when the lock is shelved Instead the Shelved Mode combination is used to open the lock without any Smart Key The default Factory Combination is set to 50...

Page 25: ...50 25 50 by sequentially pressing those six buttons The LCD will display the entered number 3 When the combination has been correctly entered the LCD will read OPr meaning Open right 4 Turn the dial r...

Page 26: ...g 5 wrong combination attempts in a row without a successful opening in between because the lock will be put into Lock Out condition displaying LCO Clearing the LCO condition in Shelved Mode requires...

Page 27: ...EC Turn the Dial to the left CCW until EC Enter Combination is displayed 2 EC Enter Shelved Mode Combination OPr Enter the current Shelved Mode combination either 50 25 50 or a changed Shelved Mode co...

Page 28: ...ll be displayed WARNING Record the new combination and store it in a secure place If this combination is lost or forgotten there is no alternate way to open the lock 12 POC Remove Change Key EOP Remov...

Page 29: ...This considerably lengthens the replenishment or emptying cycles on cash in cash out systems and at the same time the cash holding per system can be reduced This manual contains the operation procedu...

Page 30: ...ty Cassette RC30 Number 3 ea When auto stack Note 1 288mm 11 34inch 2850bills Note3 Injection of human Note2 343mm 13 50inch 3000bills Note3 Recycle Deposit Dispensing Small capacity Cassette RC31 Num...

Page 31: ...ower Body BMD Dimensions Width 325 5 3 mm 12 81 0 118inch Length 873 9 3 mm 34 41 0 118inch Height 529 8 3 mm 20 86 0 118inch Weight 76 Kg 167 55Ib except bill weight Recycle Deposit RC30 Cassette Dim...

Page 32: ...rved Bill Conditions Acceptable condition 1 Bill which is very clean and can readily be recognized as a true bill 2 Bill has sufficient life or sizing to be handled easily 3 Bill which can be manually...

Page 33: ...chine 2014 Nautilus Hyosung Inc All Rights Reserved 4 5 Unacceptable condition 1 Bill having serious wrinkles torn or broken section wherein paper fiber is broken and separation begins Wrinkle Torn Br...

Page 34: ...quate life or sizing but stained seriously 3 Bill with holes Perforated bill 4 Bill ragged and cannot be held straightly when one end is supported by a hand 20mm 0 79inch 35mm 1 38inch When the bill i...

Page 35: ...Chapter4 Bill Recycle Machine 2014 Nautilus Hyosung Inc All Rights Reserved 4 7 5 Bill with cellophane tape scotch tape etc 6 Bill with folds 7 Gradually curved bill bills tied by hand seal etc Band...

Page 36: ...Chapter4 Bill Recycle Machine Operator Manual 4 8 2014 Nautilus Hyosung Inc All Rights Reserved 8 Bill with folded lines Case 1 Case 2 Case 3 Bill distortion should not exceed 10 mm 0 39inch...

Page 37: ...ning the Lower Unit MID 1 To release the lock from BRM24 Frame press the lever A as shown in picture below Then pull the lower unit pressing lever A until the lower unit is completely taken out Lever...

Page 38: ...lose the mid transport path pressing the lever E At this time the mid transport path is closed through the 2 steps so you have to close it once again pressing the lever E Lever E Middle Transport Path...

Page 39: ...g Inc All Rights Reserved 4 11 How to Open the Lower Unit Drawer 1 Open the Drawer pulling the Lever F Lever F Lower Unit Open Lever How to Close the Lower Unit Drawer 1 Push the Drawer into the BRM24...

Page 40: ...High Capacity Cassette RC30 1 Take out the lower unit from BRM24 Frame Refer to Opening the lower unit 2 Pull out the cassette from the set guide holding the handle C Handle C Cassette Handle 3 Unfol...

Page 41: ...ing one finger entire cassette can move So please use both the thumb and forefinger 6 Check if the Stack Sheet is extruded out of the guide If it is extruded out of the guide as shown in picture below...

Page 42: ...ION Prior to replenishing the cash cassette with the notes a Fan the notes so that the notes are not sticking together b Remove all notes with holes or notes that are torn c Unfold the folded notes d...

Page 43: ...Bill Recycle Machine 2014 Nautilus Hyosung Inc All Rights Reserved 4 15 9 Fold the holder of the cassette and mount the cassette into the set guide 10 Mount the lower unit into the BRM24 Frame Refer t...

Page 44: ...t from BRM24 Frame Refer to Opening the lower unit 2 Separate the cassette from the set guide holding the handle C Handle C Cassette Handle 3 Place the Cassette on the flat surface as the picture belo...

Page 45: ...Machine 2014 Nautilus Hyosung Inc All Rights Reserved 4 17 5 Mount the cassette into the set guide Please check the direction of cassette entrance before mounting 6 Mount the lower unit into the BRM24...

Page 46: ...Inc All Rights Reserved How to Remove the Bills from the Utility Cassette To remove the bills from the Utility Cassette 1 Turn the key clockwise to separate the Utility Cassette 2 Pull the Utility Cas...

Page 47: ...and open the door as shown in picture below 4 Remove the bills from the Utility Cassette After removing the bills close the door with the key Remove the key after closing the door 5 Mount the Utility...

Page 48: ...sh the lever A in the arrow direction to release the lock Then lift up the Customer Service Module holding the handle B and fix it in the safety lock C Lever A Lock Lever of CSM Handle B Handle of CSM...

Page 49: ...SM Opening Tape Escrow 1 Push the lever A in the arrow direction to release the lock Then lift up the Tape Escrow holding the handle B and fix it in the safety lock C Lever A TE Lock Lever Handle B TE...

Page 50: ...Manual 4 22 2014 Nautilus Hyosung Inc All Rights Reserved Caution DO NOT take your hands off the handle until the upper unit is completely closed because the safety lock is released And also do NOT h...

Page 51: ...and Close the Upper Body of the Machine Open the upper body of BRM as follows 1 Pull the upper unit in the arrow direction by pulling the lever A forward Lever A Upper Unit Lock Lever Close the upper...

Page 52: ...appropriate steps based on the particular case to remove the jam Case 1 Removing a jam from the Customer Service Module 1 Turn the green knob A counterclockwise and open the door Knob A CSM Shutter Kn...

Page 53: ...Nautilus Hyosung Inc All Rights Reserved 4 25 3 Turn the knob C clockwise and completely remove the jammed bill Knob C Knob for CSM Jam Removal 4 After removing the jammed bill turn the knob A clockw...

Page 54: ...d the lever B on the front of the upper unit and pull it as shown in picture below Then the front transport path will appear Lever B Front Transport Path Open Lever 3 Turn the green knob C clockwise f...

Page 55: ...Service Module 2 Lift up the rear transport path with one hand and press the lever A with another hand to release the lock The lift up BC Bill Checker Lever A BC Lock Lever 3 While still holding the...

Page 56: ...pe Escrow and Customer Service Module Case 4 Removing a jam from Rear Transport Path 1 Open Customer Service Module and Tape Escrow 2 Turn the green knob A clockwise for the jammed bill to be shown an...

Page 57: ...Press the green button on Tape Escrow three times for 1 second 2 Remove the bill returned to Customer Service Module The function of jam removal using button is optional 3 If the jammed bill is remain...

Page 58: ...e front of transport path Knob A TE Drum Knob Knob B TE Transport Knob 5 Turn the knob A counterclockwise and remove the crumpled bill wound around the drum as shown in pictures Knob A TE Drum Knob 6...

Page 59: ...ath counterclockwise until the bill on the mid transport path moves to the end of opposite side of the path When the bill appears on the end of the opposite remove the jammed bill Knob A MID Transport...

Page 60: ...oving Jam from Center Transport Path 1 In case of the section of Drawer turn the Knob D counterclockwise and remove the bill Knob D Center Transport Knob 2 Remove the cassette from both sides and pres...

Page 61: ...cassette with bills 2 Pull the Push Plate in the arrow direction of the below picture to remove the jammed bill 3 Find the green knob A in the upper part of the internal of the cassette Knob A Knob f...

Page 62: ...e Case 9 Removing jam from UTC Utility Cassette 1 Open the door of UTC Utility Cassette and check the position of the jammed bill 2 Turn the green knob A counterclockwise and the jammed bill appears A...