Nauticam NA-502B Instruction Manual Download Page 1

 

 

Summary of Contents for NA-502B

Page 1: ...1 ...

Page 2: ...vative designs of our products We strive to achieve a high level of user friendliness by allowing stress free installation and easy operation of all important functions of the camera Each housing is individually inspected and water pressure tested to ensure optimum quality before leaving our manufacturing center Please read this manual carefully before using the housing this will maximise its perf...

Page 3: ...ontents 6 Precautions 7 Specifications 9 Identification of Parts 10 Opening and Locking the Housing 12 Preparation of the Housing 14 Installing the Monitor 20 Connecting to the Camera Housing 22 Care and Maintenance 31 Optional Accessories 32 ...

Page 4: ...uct is shipped from our facility This warranty only applies to products purchased from authorised NAUTICAM dealers and does not extend beyond the original retail purchaser HDMI and SDI cables are warranted for 4 months from the date of purchase To return your product for service please contact your regional authorized service centre s Please note that this warranty only applies when the product is...

Page 5: ...th and or placed within our products NAUTICAM accepts no liability for any loss of captured images or the inability to capture images even if it is due to the malfunctioning of our products Unauthorised modifications and or repairs of our products will automatically invalidate the warranty ...

Page 6: ...ring O ring remover CR2032 battery Lubricant Set of Allen keys Instruction manual For 17920 NA 502B H 1 HDMI A D cable in 750mm length pre installed 2 M16 HDMI bulkhead 3 HDMI D C cable in 190mm length 4 HDMI D C cable in 200mm length 5 HDMI A D cable in 750mm length For 17921 NA 502B S 1 SDI cable in 0 75m length pre installed 2 M16 SDI Bulkhead 3 SDI cable in 0 3m length ...

Page 7: ...ant provided by NAUTICAM Discontinue use immediately should you notice any leakage Store the housing in a robust shock proof container during transportation avoid transporting with any equipment such as a camera inside the housing When travelling by air do not close the housing as this may lead to a pressure difference between the atmosphere and inside the housing Care must be taken when opening t...

Page 8: ...re the product in an environment of high humidity Do not leave the housing and the monitor in direct sunlight for prolonged periods Keep out of reach of children failure to do so could result in injury Defective products should be shipped to our distributors for service unauthorized disassembling and or modifications could result in malfunction or leakage ...

Page 9: ...sion resistant polycarbonate Dimensions Width 222mm Height 122mm Depth 77mm Weight Approx 1 41kg Buoyancy Approx 20g Depth rating 100 metres Operating Temperature Normal operating temperature is between 10 C and 40 C For usage outside the stated temperature range please contact our dealers for more information ...

Page 10: ...TION OF PARTS Up selection button Monitor on off button Center button Left selection button Right selection button Down selection button Back button M16 vacuum valve Capture button Threaded holes for monitor hood 4x ...

Page 11: ...11 Housing lock safety button Ball mount Sacrificial zinc anode M16 accessory port Housing lock HDMI cable SDI cable Cable cap ...

Page 12: ...12 OPENING AND LOCKING THE HOUSING To open the housing 1 Press the housing lock safety button 2 Turn the housing lock anti clockwise for 270 until the lock reaches the Open position as shown ...

Page 13: ...Close the housing while the housing lock is in the Open position 4 Turn the housing lock clockwise for 270 until the lock reaches the lock position as shown Confirm that the white indicator line on the safety button is visible ...

Page 14: ...d in the front part of the housing is free from any foreign material the groove can be cleaned with the aid of a microfiber cloth 3 Place the main O ring into the groove first at the corners then the whole perimeter 4 Setting up the moisture alarm 1 Install the CR2032 battery provided into the battery compartment on the circuit board inside the front part of the housing ...

Page 15: ...oes into flashing blue light standby mode 3 Test the alarm by connecting the two wires near the bottom of the housing with a damp cotton bud the alarm should start giving out a repeating beep sound along with a flashing red light The beep sound and the light should keep on going for 5 seconds after the removal of the damp cotton bud ...

Page 16: ...mmended to leave the housing for at least 20mins to ensure it is sealed If the LED light changes from steady green light to rapidly flashing yellow light that means there is a leakage and please check every o ring and conduct the vacuum test again Caution Please DO NOT attempt to go over the designated vacuum level i e stop pumping when the LEDturn green Excessive vacuum level may lead to the malf...

Page 17: ...unt of temperature variation it is recommended to conduct the vacuum test in an environment where the temperature is stable 4 Please ensure that the cap is attached back to the vacuum valve before going underwater 5 Vacuum can be released by turning the vacuum release ring anti clockwise ...

Page 18: ...icates a 2nd generation PCB Steady Blue light Battery is normal goes into flashing Blue light standby mode after 5 seconds Blue and Red lights alternating Battery low Replace battery as soon as possible Goes into standby mode after 5 seconds Steady Red light Battery empty replace battery ...

Page 19: ...beeping sound Moisture is detected Flashing Yellow light Some vacuum is detected target vacuum level is not reached Steady Green light Target vacuum level is reached Rapidly flash Yellow light Vacuum is dropping Will occur only after target vacuum level is reached Rapidly flashing Red light Vacuum is totally lost Circuit stalled until switched off Will occur only after target vacuum level is reach...

Page 20: ...nstall the monitor into to the housing 1 Turn the two locking levers in the direction as shown 2 Connect the HDMI cable with L connector to the monitor s HDMI in socket as shown above or HD SDI cable to the monitor s SDI out socket ...

Page 21: ...21 3 Place the monitor inside the housing and secure the monitor by turning the two locking levers towards the monitor as shown ...

Page 22: ...ECTING TO THE CAMERA HOUSING For installing the standard HDMI bulkhead with M16 thread or M16 SDI bulkhead 3 Unscrew the M16 plug from the threaded hole with a coin 2 Tighten the HDMI or HD SDI bulkhead with a spanner ...

Page 23: ...23 3 Connect the HDMI HD SDI cable to the HDMI HD SDI bulkhead 4 Connect the HDMI HD SDI cable to the camera s HDMI HD SDI socket ...

Page 24: ...24 For installing the custom HDMI bulkhead to use with extension 1 Unscrew the M16 plug from the accessory port with a coin 2 Tighten the socket extension to the camera housing with a spanner ...

Page 25: ...25 3 Insert the HDMI cable through the threaded hole from inside of the housing 4 Connect the HDMI cable to the HDMI bulkhead ...

Page 26: ...26 5 Tighten the HDMI bulkhead by turning the threaded ring on the socket extension 6 Connect the HDMI cable to the camera s HDMI connector ...

Page 27: ...27 To connect the monitor housing to HDMI SDI bulkhead 1 Unscrew the cap off the HDMI SDI bulkhead 2 Unscrew the cap off the HDMI HD SDI cable ...

Page 28: ...28 3 Align and plug the HDMI HD SDI cable in the HDMI HD SDI bulkhead Tighten the connection by turning the threaded ring on the HDMI HD SDI cable ...

Page 29: ...ideo signal to be sent topside to a director s monitor Note Extra HD SDI bulkhead 25058 and cables 25060 for internal connection 25064 15m HD SDI Surface Feed Cable or 25065 45m HD SDI Surface Feed Cable are required Please follow below instruction for setting 1 Unscrew the M16 plug from the accessory port as shown with a coin ...

Page 30: ...30 2 Tighten the HD SDI bulkhead with a spanner 3 Connect the HD SDI cable to the HD SDI bulkhead and to the monitor SDI out socket ...

Page 31: ...31 4 Remove the cap of both HD SDI bulkhead and HD SDI Surface Feed Cable then plug the cable to the bulkhead 5 Tighten the connection by turning the threaded ring on the HD SDI cable ...

Page 32: ...emoved fromits groove with the O ring remover and inspected for damage Also check that the O ring retains its original circular shape never stretch the O ring excessively or remove it with a sharp object The O ring groove should be cleaned to ensure it is free from any salt deposit or foreign material lightly coat the O ring with the provided lubricant before reinstalling it in the groove A damage...

Page 33: ...5060 SDI cable in 0 4m length P N 25063 SDI cable in 30m length for connection between SDI Bulkheads P N 25064 25065 SDI surface monitor cable in 15m 45m length for connection from SDI Bulkhead to Surface Monitor on land P N 25059 SDI cable extension adaptor ...