XR6/XR3 Operations and Maintenance Manual
Routine maintenance
Page 4-4
Issue 3.1 2013-03-14
Interval
Every 12 months.
Parts and tools
Replacement battery. 3 V lithium coin cell, 20 mm (Nautel Part # BBLT01, Panasonic # Panasonic
CR2032).
Procedure
Perform the following steps to replace the battery:
1. Ensure ac power is being applied to the transmitter.
2. Open the front panel of the transmitter.
3. Replace the battery in XBT1 on the control/display PWB. See
mechanical drawings section at the end of the
XR6/XR3 Troubleshooting Manual
.
4. Close the front panel.
5. Check for any alarms on the graphic user interface.
(See
“Viewing alarm status” on page 2-7
Inspecting lightning protection systems
You should inspect the lightning protection systems that are connected to your XR6/XR3
transmitter, ac power, RF feedline, antenna and tower periodically to ensure that your site, equipment
and personnel are fully protected.
Interval
Every 6 months.
Parts and tools
Depends on your site, but may include a DVM, ladder, binoculars, and continuity tester.
Summary of Contents for XR6
Page 2: ......
Page 4: ......
Page 10: ...XR6 XR3 Operations and Maintenance Manual Page x Issue 3 1 2013 03 14...
Page 18: ...XR6 XR3 OPERATIONS AND MAINTENANCE MANUAL PAGE XVIII VERSION 3 1 2013 03 14...
Page 65: ...XR6 XR3 Operations and Maintenance Manual Using the event log Page 3 8 Issue 3 1 2013 03 14...
Page 71: ...XR6 XR3 Operations and Maintenance Manual Routine maintenance Page 4 6 Issue 3 1 2013 03 14...
Page 82: ......