![Nautel VX150 Installation Manual Download Page 40](http://html2.mh-extra.com/html/nautel/vx150/vx150_installation-manual_3526012040.webp)
VX150 TO VX2 INSTALLATION MANUAL
PROGRAM INPUTS
PAGE 1.7.2
VERSION 0.3 2021-01-14
NOTE
: Transmitters are factory set to provide 100% modulation (± 75 kHz) with an analog L/R input
level of precisely 1.24 V rms (+4.7 dBu).
MPX/SCA Inputs
NOTE
:
Transmitters are factory set to provide 10% modulation (± 7.5 kHz) with an SCA input level of
precisely 1.0 V rms (2.8 V pk-pk). If the main program source is MPX input, meters for MPX SCA will
display “N/A”.
Two unbalanced inputs (20 kHz to 100 kHz) are provided on the
MPX SCA1 IN
and
MPX SCA2 IN
female BNC connectors, which accept pre-modulated SCA information. The levels are nominally 2.8 V
pk-pk for ± 75 kHz carrier deviation, and are adjustable between 1.0 V and 5 V pk-pk. The input
impedance for each input is 10 k
.
Digital Inputs
Each VX series transmitter exciter accepts the following digital inputs:
AES/EBU Inputs
The VX series transmitter accepts AES/EBU digital audio via the
AES/EBU IN 1 and AES/EBU IN 2,
3-pin
female XLR connectors (110
balanced; supports sample rates between 32 to 192 kHz). The VX series
transmitter's remote AUI or front panel UI allows for configuration of the audio input mode (left, right
or stereo) and level (in dBfs). Default factory setting is -4.0 dBFS
.
RBDS/RDS Input
NOTE
: The VX transmitter also supports stand-alone RBDS/RDS operation. In this mode, RBDS/RDS
parameters are configured through the remote AUI or front panel UI.
The VX transmitter accepts UECP or ASCII data for its internal RBDS/RDS generator via RS-232 on the
RDS/RBDS (A1J3A)
9-pin, female D-type connector. The data is framed and modulated on a 57 kHz sub-
carrier, which forms part of the composite signal.
Other Features
Carrier Frequency and Pilot Phase Control (10 MHz and 1 PPS IN)
Each VX series transmitter provides carrier frequency and pilot phase control from a precision GPS
reference on the exciter’s
10 MHz IN
female BNC connector (between 0.5 V and 2 V pk-pk sine wave
input; 50
) and
1 PPS IN
female BNC connector (5 V TTL input level, 10 k
).
Summary of Contents for VX150
Page 2: ......
Page 4: ......
Page 10: ...VX150 TO VX2 INSTALLATION MANUAL PAGE VIII VERSION 0 3 2021 01 14...
Page 14: ...VX150 TO VX2 INSTALLATION MANUAL PAGE XIV VERSION 0 3 2021 01 14...
Page 22: ...VX150 TO VX2 INSTALLATION MANUAL PAGE XXII VERSION 0 3 2021 01 14...
Page 26: ...VX150 TO VX2 INSTALLATION MANUAL DESCRIPTION PAGE 1 1 4 VERSION 0 3 2021 01 14...
Page 36: ...VX150 TO VX2 INSTALLATION MANUAL ELECTRICAL REQUIREMENTS PAGE 1 5 4 VERSION 0 3 2021 01 14...
Page 38: ...VX150 TO VX2 INSTALLATION MANUAL RF OUTPUT REQUIREMENTS PAGE 1 6 2 VERSION 0 3 2021 01 14...
Page 42: ...VX150 TO VX2 INSTALLATION MANUAL PROGRAM INPUTS PAGE 1 7 4 VERSION 0 3 2021 01 14...
Page 44: ......
Page 54: ...VX150 TO VX2 INSTALLATION MANUAL CONTROL AND MONITOR WIRING PAGE 1 8 10 VERSION 0 3 2021 01 14...
Page 74: ...VX150 TO VX2 INSTALLATION MANUAL PARTS AND TOOLS PAGE 1 12 4 VERSION 0 3 2021 01 14...
Page 84: ...VX LP INSTALLATION MANUAL LIST OF TERMS PAGE 1 14 2 VERSION 0 3 2021 01 14...
Page 85: ......