VX150 TO VX2 TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
VERSION 2.0 2023-04-20
PAGE 3.1.29
PS Not Installed
The PA power supply has been removed as
indicated by the absence of a grounded pin
connection on the power supply connector.
The PA Power Supply is installed, and the
present pin has been grounded by the power
supply.
Install Power supply.
Verify there is no obstruction in the
power supply connector.
The PS Present pin is measured using an
ADC on the Power Supply Interface PWB.
If problems persist check connections to
this board.
SCA MPX 1/2 Low Composite
The MPX1/2 input level has fallen below the
user configured low audio threshold for longer
than the user configured timeout.
The MPX1/2 input must be configured as a
composite SCA source in the active preset for
this alarm to trigger.
The SCA MPX 1/2 Low Alarm must be enabled
in the active preset for this alarm to occur
.
T
his alarm will clear immediately when the
MPX1/2 input level has increased above the
configured threshold.
Performing an alarm reset will clear this alarm
and reset the timeout.
Check the composite feed connected to
the MPX1/2 input. The most likely cause
of this alarm is an interruption in
composite distribution to the transmitter.
Verify that the threshold level
programmed in the active preset is below
the normal input level by checking the
MPX1/2 meter.
Verify that the configured timeout is long
enough to cover any silence or dips in
signal level.
SCA1 AES1 Left Low Audio
The AES1 Left audio input level has fallen
below the user configured low audio
threshold for longer than the user configured
timeout.
The AES1 input must be configured as a SCA
source in the active preset for this alarm to
trigger.
The SCA 1 Low Alarm must be enabled in the
active preset for this alarm to occur.
This alarm will clear immediately when the
AES1 left input level has increased above the
configured threshold.
Performing an alarm reset will clear this alarm
and reset the timeout.
Check the audio feed connected to the
AES1 input. The most likely cause of this
alarm is an interruption in audio
distribution to the transmitter.
Verify that the threshold level
programmed in the active preset is below
the normal input level by checking the
AES1 Left meter.
Verify that the configured timeout is long
enough to cover any silence or dips in
signal level.
Alarm Name
Trigger Conditions
Clear Conditions
Troubleshooting
Summary of Contents for VX150
Page 2: ......
Page 4: ......
Page 8: ...VX150 TO VX2 TROUBLESHOOTING MANUAL PAGE VIII VERSION 2 0 2023 04 20...
Page 42: ...RESPONDING TO ALARMS VX150 TO VX2 TROUBLESHOOTING MANUAL PAGE 3 1 34 VERSION 2 0 2023 04 20...
Page 132: ......
Page 136: ...VX150 TO VX2 TROUBLESHOOTING MANUAL WIRING INFORMATION PAGE 3 3 4 VERSION 2 0 2023 04 20...
Page 142: ...VX150 TO VX2 TROUBLESHOOTING MANUAL ELECTRICAL SCHEMATICS PAGE 3 4 6 VERSION 2 0 2023 04 20...
Page 168: ...VERSION 2 0 2023 04 20 MD 6 Figure MD 6 NAPI189 Analog Audio PWB...
Page 169: ...VERSION 2 0 2023 04 20 MD 7 Figure MD 7 NAPI187A System Interface PWB...
Page 171: ...VERSION 2 0 2023 04 20 MD 9 Figure MD 9 NAPI188 Power Supply Interface PWB VX1 VX1 5 VX2...
Page 172: ...VERSION 2 0 2023 04 20 MD 10 Figure MD 10 NAPI193 Front Panel User Interface PWB...
Page 173: ...VERSION 2 0 2023 04 20 MD 11 Figure MD 11 NAPA41 Pre Amp IPA PWB...
Page 174: ...VERSION 2 0 2023 04 20 MD 12 Figure MD 12 NAPA40A Power Amplifier PWB...
Page 175: ...VERSION 2 0 2023 04 20 MD 13 Figure MD 13 NAPF16A Low Pass Filter PWB...
Page 176: ...VERSION 2 0 2023 04 20 MD 14 Figure MD 14 NAPP15A Directional Coupler Bottom PWB...
Page 177: ...VERSION 2 0 2023 04 20 MD 15 Figure MD 15 NAPH15 2 Way Splitter PWB VX1 5 VX2...
Page 178: ...VERSION 2 0 2023 04 20 MD 16 Figure MD 16 2 Way Combiner PWB Nautel Part PU03B VX1 5 VX2...
Page 180: ...VX LP TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 3 6 2 VERSION 2 0 2023 04 20...
Page 181: ......