FPGA Failure
The FPGA was either not programmed or
failed to respond after being programmed as
part of the configuration process that occurs
when the Exciter starts up.
The FPGA responded after being programmed
as part of the configuration process that
occurs when the Exciter starts up.
The likely causes are a missing or corrupt
FPGA image file as a result of a damaged
SD Card. Either replace the SD Card or
perform a Software Update to install a
new FPGA image.
The next most likely cause is a damaged
FPGA. Consider replacement of the
Exciter PWB. See
Display Failure
The front panel display module has not
completed a successful update in at least
150us.
This alarm will clear immediately on a
successful update of the display.
Check display connections and verify
display operation locally.
Consider replacing the display if
unresponsive. See
Interface (FPUI) Display
Replacement on page 3.1.54
High Ambient Temperature
Shutback
The Ambient Temperature meter has
exceeded 55
°
C for at least 1 minute.
This alarm will temporarily inhibit RF until
cleared to protect the transmitter from
overheating.
This alarm will clear automatically if the
Ambient Temperature meter falls below 50
°
C,
restoring RF operation
Check site cooling.
Ensure the Transmitter’s air intake is
unobstructed.
High Ambient Temperature
Warning
The Ambient Temperature meter has
exceeded 50
°
C for at least 30 seconds.
This alarm will clear immediately if the
Ambient Temperature meter falls below 45
°
C.
This alarm will be suppressed if the High
Ambient Temperature Shutback Alarm is
active.
Check site cooling.
Ensure the transmitter’s air intake is
unobstructed.
High Forward Power
The Forward Power meter exceeds 110% of
the Output Power setpoint for at least 1
second.
The Forward Power meter is less than 110%
of the Output Power Setpoint for at least 1
second.
This alarm may trigger when
substantially reducing the transmitter’s
setpoint.
If the alarm is persistent or reoccurring,
AC cycle transmitter. If the behavior
persists contact Nautel.
Alarm Name
Trigger Conditions
Clear Conditions
Troubleshooting
Summary of Contents for VX150
Page 2: ......
Page 4: ......
Page 8: ...VX150 TO VX2 TROUBLESHOOTING MANUAL PAGE VIII VERSION 2 0 2023 04 20...
Page 42: ...RESPONDING TO ALARMS VX150 TO VX2 TROUBLESHOOTING MANUAL PAGE 3 1 34 VERSION 2 0 2023 04 20...
Page 132: ......
Page 136: ...VX150 TO VX2 TROUBLESHOOTING MANUAL WIRING INFORMATION PAGE 3 3 4 VERSION 2 0 2023 04 20...
Page 142: ...VX150 TO VX2 TROUBLESHOOTING MANUAL ELECTRICAL SCHEMATICS PAGE 3 4 6 VERSION 2 0 2023 04 20...
Page 168: ...VERSION 2 0 2023 04 20 MD 6 Figure MD 6 NAPI189 Analog Audio PWB...
Page 169: ...VERSION 2 0 2023 04 20 MD 7 Figure MD 7 NAPI187A System Interface PWB...
Page 171: ...VERSION 2 0 2023 04 20 MD 9 Figure MD 9 NAPI188 Power Supply Interface PWB VX1 VX1 5 VX2...
Page 172: ...VERSION 2 0 2023 04 20 MD 10 Figure MD 10 NAPI193 Front Panel User Interface PWB...
Page 173: ...VERSION 2 0 2023 04 20 MD 11 Figure MD 11 NAPA41 Pre Amp IPA PWB...
Page 174: ...VERSION 2 0 2023 04 20 MD 12 Figure MD 12 NAPA40A Power Amplifier PWB...
Page 175: ...VERSION 2 0 2023 04 20 MD 13 Figure MD 13 NAPF16A Low Pass Filter PWB...
Page 176: ...VERSION 2 0 2023 04 20 MD 14 Figure MD 14 NAPP15A Directional Coupler Bottom PWB...
Page 177: ...VERSION 2 0 2023 04 20 MD 15 Figure MD 15 NAPH15 2 Way Splitter PWB VX1 5 VX2...
Page 178: ...VERSION 2 0 2023 04 20 MD 16 Figure MD 16 2 Way Combiner PWB Nautel Part PU03B VX1 5 VX2...
Page 180: ...VX LP TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 3 6 2 VERSION 2 0 2023 04 20...
Page 181: ......