VX150 TO VX2 TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
VERSION 2.0 2023-04-20
PAGE 3.1.17
Exciter DC Voltage Failure
Any of the following Exciter PWB voltage
meters meet the stated criteria for a period of
at least 5 seconds:
Exciter PWB +5V Meter measures less
than +2.5 V or greater than +7.5 V
Exciter PWB +3.3V Meter measures less
than +1.65 V or greater than +4.95 V
Exciter PWB +2.5V Meter measures less
than +1.25 V or greater than +3.75 V
Exciter PWB +1.5V Meter measures less
than +0.75 V or greater than +2.25 V
Exciter PWB +1.1V Meter measures less
than +0.55 V or greater than +1.65 V
All of the following Analog Audio PWB
voltage meters meet the stated criteria for a
period of at least 5 seconds:
Exciter PWB +5V Meter measures
b2.5 V and +7.5 V
Exciter PWB +3.3V Meter measures
b1.65 V and +4.95 V
Exciter PWB +2.5V Meter measures
b1.25 V and +3.75 V
Exciter PWB +1.5V Meter measures
b0.75 V and +2.25 V
Exciter PWB +1.1V Meter measures
b0.55 V and +1.65 V
If the Exciter PWB +12V Failure alarm is
present, this is the most likely cause, so
refer to the troubleshooting for that
alarm.
Check the corresponding voltage test
points on the Exciter PWB using a digital
multimeter.
The next most likely cause is a
component failure on the Exciter PWB.
Consider replacement of the Exciter PWB.
See
.
Exciter Fault
Summary alarm that is triggered if any of the
following alarms are triggered:
E12V Failure
Exciter DC Voltage Failure
PGA Failure
Invalid FPGA Image Signature
Cleared if all of the following alarms are
cleared:
E12V Failure
Exciter DC Voltage Failure
FPGA Failure
Invalid FPGA Image Signature
Summary alarm to indicate a possible
serious fault with the Exciter PWB. See
the troubleshooting for the associated
alarms in order to clear this alarm.
External Interlock
Open connection between pins 1 and 2 on the
transmitter’s Interlock connector (Exciter J7).
Closed connection between pins 1 and 2 on
the Transmitter’s Interlock connector.
If integrated in a site interlock system,
then verify the status of that interlock
connection.
If using a jumper, verify the presence of
a jumper by examining transmitter rear
panel Interlock connector.
A mating connector and jumper are
installed in the Transmitter Interlock
connector before shipping.
Alarm Name
Trigger Conditions
Clear Conditions
Troubleshooting
Summary of Contents for VX150
Page 2: ......
Page 4: ......
Page 8: ...VX150 TO VX2 TROUBLESHOOTING MANUAL PAGE VIII VERSION 2 0 2023 04 20...
Page 42: ...RESPONDING TO ALARMS VX150 TO VX2 TROUBLESHOOTING MANUAL PAGE 3 1 34 VERSION 2 0 2023 04 20...
Page 132: ......
Page 136: ...VX150 TO VX2 TROUBLESHOOTING MANUAL WIRING INFORMATION PAGE 3 3 4 VERSION 2 0 2023 04 20...
Page 142: ...VX150 TO VX2 TROUBLESHOOTING MANUAL ELECTRICAL SCHEMATICS PAGE 3 4 6 VERSION 2 0 2023 04 20...
Page 168: ...VERSION 2 0 2023 04 20 MD 6 Figure MD 6 NAPI189 Analog Audio PWB...
Page 169: ...VERSION 2 0 2023 04 20 MD 7 Figure MD 7 NAPI187A System Interface PWB...
Page 171: ...VERSION 2 0 2023 04 20 MD 9 Figure MD 9 NAPI188 Power Supply Interface PWB VX1 VX1 5 VX2...
Page 172: ...VERSION 2 0 2023 04 20 MD 10 Figure MD 10 NAPI193 Front Panel User Interface PWB...
Page 173: ...VERSION 2 0 2023 04 20 MD 11 Figure MD 11 NAPA41 Pre Amp IPA PWB...
Page 174: ...VERSION 2 0 2023 04 20 MD 12 Figure MD 12 NAPA40A Power Amplifier PWB...
Page 175: ...VERSION 2 0 2023 04 20 MD 13 Figure MD 13 NAPF16A Low Pass Filter PWB...
Page 176: ...VERSION 2 0 2023 04 20 MD 14 Figure MD 14 NAPP15A Directional Coupler Bottom PWB...
Page 177: ...VERSION 2 0 2023 04 20 MD 15 Figure MD 15 NAPH15 2 Way Splitter PWB VX1 5 VX2...
Page 178: ...VERSION 2 0 2023 04 20 MD 16 Figure MD 16 2 Way Combiner PWB Nautel Part PU03B VX1 5 VX2...
Page 180: ...VX LP TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 3 6 2 VERSION 2 0 2023 04 20...
Page 181: ......