RESPONDING TO ALARMS
VX150 TO VX2 TROUBLESHOOTING MANUAL
PAGE 3.1.8
VERSION 2.0 2023-04-20
AES1/2 Right Low Audio
The AES1/2 Right audio input level has fallen
below the user configured low audio
threshold for longer than the user configured
timeout.
The AES1/2 input must be configured as the
main audio source in the active preset for this
alarm to trigger.
The Main Audio Low Audio Alarm must be
enabled in the active preset for this alarm to
occur.
The presence of this alarm will cause a switch
to the backup audio source if configured in
the active preset.
This alarm will clear immediately when the
AES1/2 Right audio input level has increased
above the configured threshold
Performing an alarm reset will clear this
alarm and reset the timeout.
Clearing this alarm will cause switch back to
the main audio source if the transmitter was
previously operating on the backup source.
Check the audio feed connected to the
AES1/2 input. The most likely cause of
this alarm is an interruption in audio
distribution to the transmitter.
Verify that the threshold level
programmed in the active preset is
below the normal audio input level by
checking the AES1/2 Right meter.
Verify that the configured timeout is long
enough to cover any silence or dips in
signal level.
AES1/2 Right Low Backup
Audio
The AES1/2 Right audio input level has fallen
below the user configured low audio
threshold for longer than the user configured
timeout.
The AES1/2 input must be configured as the
backup audio source in the active preset for
this alarm to trigger.
The Backup Low Audio Alarm must be
enabled in the preset for this alarm to occur.
The presence of this alarm will prevent a
change to the backup audio source if
configured in the active preset.
This alarm will clear immediately when the
AES1/2 Right audio input level has increased
above the configured threshold.
Performing an alarm reset will clear this alarm
and reset the timeout.
Check the audio feed connected to the
AES1/2 input. The most likely cause of
this alarm is an interruption in audio
distribution to the transmitter.
Verify that the threshold level
programmed in the active preset is
below the normal audio input level by
checking the AES1/2 Right meter.
Verify that the configured timeout is long
enough to cover any silence or dips in
signal level.
Alarm Name
Trigger Conditions
Clear Conditions
Troubleshooting
Summary of Contents for VX150
Page 2: ......
Page 4: ......
Page 8: ...VX150 TO VX2 TROUBLESHOOTING MANUAL PAGE VIII VERSION 2 0 2023 04 20...
Page 42: ...RESPONDING TO ALARMS VX150 TO VX2 TROUBLESHOOTING MANUAL PAGE 3 1 34 VERSION 2 0 2023 04 20...
Page 132: ......
Page 136: ...VX150 TO VX2 TROUBLESHOOTING MANUAL WIRING INFORMATION PAGE 3 3 4 VERSION 2 0 2023 04 20...
Page 142: ...VX150 TO VX2 TROUBLESHOOTING MANUAL ELECTRICAL SCHEMATICS PAGE 3 4 6 VERSION 2 0 2023 04 20...
Page 168: ...VERSION 2 0 2023 04 20 MD 6 Figure MD 6 NAPI189 Analog Audio PWB...
Page 169: ...VERSION 2 0 2023 04 20 MD 7 Figure MD 7 NAPI187A System Interface PWB...
Page 171: ...VERSION 2 0 2023 04 20 MD 9 Figure MD 9 NAPI188 Power Supply Interface PWB VX1 VX1 5 VX2...
Page 172: ...VERSION 2 0 2023 04 20 MD 10 Figure MD 10 NAPI193 Front Panel User Interface PWB...
Page 173: ...VERSION 2 0 2023 04 20 MD 11 Figure MD 11 NAPA41 Pre Amp IPA PWB...
Page 174: ...VERSION 2 0 2023 04 20 MD 12 Figure MD 12 NAPA40A Power Amplifier PWB...
Page 175: ...VERSION 2 0 2023 04 20 MD 13 Figure MD 13 NAPF16A Low Pass Filter PWB...
Page 176: ...VERSION 2 0 2023 04 20 MD 14 Figure MD 14 NAPP15A Directional Coupler Bottom PWB...
Page 177: ...VERSION 2 0 2023 04 20 MD 15 Figure MD 15 NAPH15 2 Way Splitter PWB VX1 5 VX2...
Page 178: ...VERSION 2 0 2023 04 20 MD 16 Figure MD 16 2 Way Combiner PWB Nautel Part PU03B VX1 5 VX2...
Page 180: ...VX LP TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 3 6 2 VERSION 2 0 2023 04 20...
Page 181: ......