VX150 TO VX2 TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
PAGE 3.1.6
VERSION 2.0 2023-04-20
Remote AUI Alarms Page Checks
If an alarm exists and is being recognized by the transmitter, it is displayed on the
Alarms
page (see
). The warning symbol in the upper, right section of the remote AUI dashboard (any page)
will be amber or red when an alarm is present.
Figure 3.1.3: AUI Alarms Page
1.
Click the warning symbol (or select Menu -> Alarms) to go to the
Alarms
page (see
View the list of active faults. Alarms are listed by their name (
Alarm
Detail column).
2.
Attempt to clear any latching alarms by pressing the
Reset Latched Alarm
s icon at the top, left of
the Alarms screen If the alarm persists, it will not be cleared from the display.
3.
Locate the alarm name in
to determine the cause of the alarm and
perform any recommended procedures in the
Troubleshooting
column. This may also lead to
replacing a suspect PWB, power supply or fan, as detailed in
PA Resistance Checks, on page 3.1.35
NOTE
:
contains a column for most alarms that can occur, sorted
alphanumerically for each sub-system, including both the names displayed on the remote AUI and, if
different, the front panel display. The
Troubleshooting
column provides a brief description of the
alarm, troubleshooting tips and a cross-reference to more detailed troubleshooting, as applicable.
4.
If troubleshooting and subsequent replacement of a suspect PWB or module causes the alarm to
disappear from the
Alarms
page, the alarm has been successfully cleared. If the fault condition
does not clear, contact Nautel.
NOTE
:
Before undertaking any troubleshooting, record all remote AUI meter readings and note if any
other alarms are displayed on the
Alarms
page
.
Record all alarms. The most convenient way to do this
is by using the remote AUI’s Menu -> Reports page to download a report of the Alarm History (see
“Alarm History” in the Operations & Maintenance Manual). Another method is to use a web browser
over a LAN connection to save screen shots of critical status, meter and alarm pages. Go to the
Dashboard -> Meters
page to view (and save) detailed information (see “Viewing Meters” in the
Operations & Maintenance Manual).
Summary of Contents for VX150
Page 2: ......
Page 4: ......
Page 8: ...VX150 TO VX2 TROUBLESHOOTING MANUAL PAGE VIII VERSION 2 0 2023 04 20...
Page 42: ...RESPONDING TO ALARMS VX150 TO VX2 TROUBLESHOOTING MANUAL PAGE 3 1 34 VERSION 2 0 2023 04 20...
Page 132: ......
Page 136: ...VX150 TO VX2 TROUBLESHOOTING MANUAL WIRING INFORMATION PAGE 3 3 4 VERSION 2 0 2023 04 20...
Page 142: ...VX150 TO VX2 TROUBLESHOOTING MANUAL ELECTRICAL SCHEMATICS PAGE 3 4 6 VERSION 2 0 2023 04 20...
Page 168: ...VERSION 2 0 2023 04 20 MD 6 Figure MD 6 NAPI189 Analog Audio PWB...
Page 169: ...VERSION 2 0 2023 04 20 MD 7 Figure MD 7 NAPI187A System Interface PWB...
Page 171: ...VERSION 2 0 2023 04 20 MD 9 Figure MD 9 NAPI188 Power Supply Interface PWB VX1 VX1 5 VX2...
Page 172: ...VERSION 2 0 2023 04 20 MD 10 Figure MD 10 NAPI193 Front Panel User Interface PWB...
Page 173: ...VERSION 2 0 2023 04 20 MD 11 Figure MD 11 NAPA41 Pre Amp IPA PWB...
Page 174: ...VERSION 2 0 2023 04 20 MD 12 Figure MD 12 NAPA40A Power Amplifier PWB...
Page 175: ...VERSION 2 0 2023 04 20 MD 13 Figure MD 13 NAPF16A Low Pass Filter PWB...
Page 176: ...VERSION 2 0 2023 04 20 MD 14 Figure MD 14 NAPP15A Directional Coupler Bottom PWB...
Page 177: ...VERSION 2 0 2023 04 20 MD 15 Figure MD 15 NAPH15 2 Way Splitter PWB VX1 5 VX2...
Page 178: ...VERSION 2 0 2023 04 20 MD 16 Figure MD 16 2 Way Combiner PWB Nautel Part PU03B VX1 5 VX2...
Page 180: ...VX LP TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 3 6 2 VERSION 2 0 2023 04 20...
Page 181: ......