NX5 PRE-INSTALLATION MANUAL
COOLING REQUIREMENTS
PAGE 1.4.4
VERSION 0.1 2015-08-01
Table 1.4.1: Cooling Requirements for the NX5
Note:
Although normal program audio is generally equivalent to 50-75% continuous tone modulation,
Nautel recommends you design the cooling system for 100% continuous tone modulation, to allow
suffiicient overhead and for testing purposes.
Closed Loop or Forced Air Cooling Systems
Closed loop or forced air cooling systems can be used, if:
the air is well filtered to prevent dust and insects from entering the transmitter, and
a minimum of 375 cubic feet per minute (CFM) is supplied to the intake duct. If you are
ducting intake air to the transmitter, make sure to compensate for any pressure loss in the
ducting system when selecting an appropriate fan.
Heating
The transmitter room must contain a heating system that will ensure the ambient air temperature does
not drop below 0°C (32°F).
Carrier
power out
(W)
Modulation
depth
(m x100)
Average
power out
(W)
Waste heat
(W)
Waste heat
(BTU/hour)
Air conditioning
required in a closed
system (tonnes)
5,000
100%
7,500
1221
4167
0.35
5,000
75%
6,407
1043
3559
0.30
5,000
50%
5,625
916
3125
0.26
Summary of Contents for NX5 AM
Page 2: ......
Page 4: ......
Page 8: ...NX5 PRE INSTALLATION MANUAL TABLE OF CONTENTS PAGE 1 VIII VERSION 0 1 2015 08 01 ...
Page 10: ...NX5 PRE INSTALLATION MANUAL PAGE 1 X VERSION 0 1 2015 08 01 ...
Page 22: ...NX5 PRE INSTALLATION MANUAL PAGE 1 XXII VERSION 0 1 2015 08 01 ...
Page 79: ...NX5 PRE INSTALLATION MANUAL PARTS AND TOOLS PAGE 1 9 4 VERSION 0 1 2015 08 01 ...
Page 85: ...NX5 PRE INSTALLATION MANUAL PRE INSTALLATION ASSISTANCE PAGE 1 10 6 VERSION 0 1 2015 08 01 ...
Page 88: ......