NV30LT-N OPERATIONS & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
VERSION 0.1 2015-03-01
PAGE 3.2.155
Analog Outputs - Front Panel
Using the
Analog Outputs
screens (see
Figure 3.2.134 on page 3.2.152
), you can view the levels of
four pre-defined analog outputs that are representative of critical transmitter parameters.
Nautel sets analog output defaults prior to shipping. There are no configuration options. They are for
monitoring purposes only. See the NV30LT-N Pre-installation Manual for details.
Figure 3.2.137: Analog Outputs Screens
Use the up and down buttons to select the desired analog output (1 through 4) from the list. Each
screen shows the analog output parameter (e.g., Forward Power, Reflected Power, Avg PA Volts or Total
PA Current), as well as the meter reading (actual and full-scale) and the output pin voltage (actual and
full-scale). Press cancel (
X
) to return to the previous menu.
NOTE
: The analog output’s
Output
voltage reading reflects the value that can be measured at the
associated remote analog output pin for the given
Meter
value. See the Pre-installation Manual for
actual remote analog output pin assignments.