GV5/GV3.5 OPERATIONS & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
PAGE 3.2.172
VERSION 0.2 2014-07-23
Ramp-Up Speed Setting
NOTE
: The ramp-up speed setting is only available using the controller UI.
From the controller UI, you can set the transmitter’s ramp-up speed. This setting establishes the time it
takes the transmitter to ramp up from 0 W to full power. At 100%, ramp-up speed is approximately
seven seconds. For a setting of 50%, ramp-up would be approximately 14 seconds. For a setting of
25%, ramp-up would be approximately 28 seconds. In multi-transmitter systems that are on a common
generator or power grid, adjusting the ramp-up speed can be used to reduce the transient load on the
source during an ac power recovery (i.e., after a power failure or changeover to a generator).
To view the
Ramp-up Speed
screen, select
User Settings -> Ramp-up Speed
from the
Main Menu
(see
).
Figure 3.2.148: Ramp-up Speed Screen
Use the up and down buttons to select a ramp-up speed between 1 and 100% (in 1% increments),
noting 100% represents approximately seven seconds (0 W to full power). The default setting is 100%
(approximately Press the accept (checkmark) button to save the change. Press
X
to abort the reset and
return to the previous menu.
Summary of Contents for GV3.5
Page 2: ......
Page 4: ......
Page 8: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL PAGE 3 VIII VERSION 0 2 2014 07 23...
Page 16: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL DESCRIPTION PAGE 3 1 8 VERSION 0 2 2014 07 23...
Page 18: ...VERSION 0 2 2014 07 23 PAGE 3 1 10 LJXUH 9 9 XGLR 3DWK ORFN LDJUDP...
Page 239: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL ROUTINE MAINTENANCE PAGE 3 3 10 VERSION 0 2 2014 07 23...
Page 249: ...GV5 GV3 5 OPERATIONS MAINTENANCE MANUAL LIST OF TERMS PAGE 3 5 2 VERSION 0 2 2014 07 23...
Page 250: ......