Electronic pellet burner controller – NPBC-V3C-K / NPBC-V4C-K / NPBC-V4E-K
Electronic Pellet Burner Controller
FOR
DRY
PELLET
STOVE
NPBC-V3C-KNPBC-V4C-K
NPBC-V4E-K
S
OFTWARE
VERSION
57/28
User Manual / ver3.8
Page 3 of 33
Page 1: ...nic pellet burner controller NPBC V3C K NPBC V4C K NPBC V4E K Electronic Pellet Burner Controller FOR DRY PELLET STOVE NPBC V3C K NPBC V4C K NPBC V4E K SOFTWARE VERSION 57 28 User Manual ver3 8 Page 3...
Page 2: ...r scheduled to turn it off in 10 minutes or less the burner will remain off because otherwise the extinguishing procedure may begin before the fire is stabilized If OD input activates during Ignition...
Page 3: ...l of the Control module for connection with a computer with software for direct control and monitoring Controllers NPBC V3C K NPBC V4C K NPBC V4E K are designed to run burners that detect the burning...
Page 4: ...r fan High temperature sensor pt100 for fire detection by measuring the temperature of the exhaust gases Thermostat to control the back burning Temperature sensor to control the room temperature A pot...
Page 5: ...y using the pt100 temperature sensor After the ignition it starts increasing and the controller constantly monitors the difference between the current temperature and the initial value If the differen...
Page 6: ...measures the temperature of the exhaust gases Then it monitors the difference between the current and the initial value during the extinction When the difference gets equal or higher than the paramet...
Page 7: ...User Manual ver3 8 Page 3 of 33 Data burner s work phase table 1 or registered error table 2 Menu Navigation buttons with different functions depending on the current menu On Off Micro USB Ambient Te...
Page 8: ...anually Examples for such messages are Back burning Boiler Frost etc They can be cleaned only by pressing and holding the left navigation button for 2 seconds while on main screen The information fiel...
Page 9: ...shing While in Standby mode the burner doesn t work If it was on right before switching to this mode it will instantly start the extinguishing procedure It needs some time to completely put down the f...
Page 10: ...burner remains off and a warning message is displayed on the screen As soon as any of the timers is activated the burner will switch to Timers mode automatically How to change the set temperature Pres...
Page 11: ...gram is equally divided for 24 hours and the vertical axis represents the consumed pellets in kilograms Above the chart is the corresponding date for the currently displayed information and below is t...
Page 12: ...of the fields ID unique identification number for each modem IP Modem s IP address WiFi mode Modem s current state can be any of the following Idle No connection with WiFi router Access point The mod...
Page 13: ...ror messages there is a three tone alarm signal Some of the error messages automatically disappear after the reason for the message is no longer present Others can be dismissed by holding the left nav...
Page 14: ...re than 2 seconds to enter the Factory settings If the option for an access code has been activated only users who know it can access the Factory settings The controller has different types of menus T...
Page 15: ...nction The numerical parameters are restricted in certain range of values When the end of the range is reached the value stops changing despite the remaining sound signal for pressed button Press and...
Page 16: ...he date After confirming the settings with the Menu button the seconds start from 0 only if the time has been changed The automatic setting is available only if the controller is equipped with a WiFi...
Page 17: ...r to stay off The time in the column On must be before the time in the column Off If necessary set the Off time first to provide larger range for the On setting When using timers to control the burner...
Page 18: ...All parameters for each profile must be set from Burning Setup menu in Factory Settings Display Change the brightness of the display if necessary Convection Fan Setting the temperature for switch on...
Page 19: ...lets If 370 seconds are not enough repeat this step several times When the auger is full stop the manual feeding 3 Place a bucket or another tank at the end of the auger motor to collect the pellets 4...
Page 20: ...onnection this menu helps with its initial setting or when changing the WiFi network Press the Menu button to exit this screen without making any changes Press the down navigation button to start the...
Page 21: ...ation buttons to change the value for each position and the left and right buttons to switch between positions Confirm the code with the Menu button Some of the parameters in the Factory settings are...
Page 22: ...time to get back to its initial position Put a check sign on the parameter FC output and after every cleaning procedure the controller will wait for the actuator to get back for as long as the output...
Page 23: ...pend if the temperature of the boiler is still increasing when it gets higher than the set temperature with as many degrees as set in the parameter Overheating the burner will turn off immediately Use...
Page 24: ...Safety Setup If the temperature of the exhaust gases gets higher than the value of the parameter Warning in this menu the controller displays a warning message If the temperature of the exhaust gases...
Page 25: ...ble the code check the check box enter the code and then repeat it If you use less than 6 digits make sure to use the same ones when you repeat the code If it is correctly set the next access to the F...
Page 26: ...inction and then ignites again Set the time interval between two automatic cleaning procedures from the parameter Cycle min Ignition This menu contains all ignition parameters If the first ignition at...
Page 27: ...ng to the boiler s temperature P1 P2 P3 and Suspend power levels the settings for these power levels are identical Set the active time of the auger to load a portion of pellets Feed Sec and the cycle...
Page 28: ...bers to cool down so the next portion can easily ignite Interm Clean This menu sets the intermediate cleaning which is performed while the fire is burning The fans temporary increase their speed which...
Page 29: ...and the Executive module s version is missing there is a communication problem between the modules or the Executive module is not working To locate the problem check the Executive module s green LED...
Page 30: ...C 0 60 20 Extinction C 0 60 40 Extinguishing time minutes 0 60 5 Power Modulation P3 T C 2 10 4 P2 T C 1 9 2 P1 T C 0 8 0 Duration minutes 0 120 20 Overheating C 00 10 2 Cleaning Start Fan seconds 0...
Page 31: ...120 30 Fan seconds 0 100 50 Exhaust fan speed 0 100 50 Setup 3 Feed seconds 0 1 25 0 5 0 Cycle seconds 4 120 30 Fan speed 0 100 100 Exhaust fan speed 0 100 100 Suspend Feed seconds 0 1 25 0 2 0 Cycle...