background image

 

UT150/SC  

The UT150/SC features four speed settings and is supplied 
complete with fixing brackets, rubber couplers and anti-
vibration connectors. 
 

FUNCTION 

The centrifugal in-line fan UT150/SC fan is used as an 
under-floor extract and ventilation system designed to 
remove gas from underneath the floor of a house and vent 
into the atmosphere through a pipe. 
There is a calibrated scale on the integral fan speed 
controller 25,50,75 and 100%.  It is usual to set it at 50% for 
levels of approx. 200 plus Bqs up to approx. 1500bqs.  The 
lower and higher settings are generally for use after a re-
test or if the levels are exceptionally high. 
 
Avoid installing the fan on an occupied bedroom wall if 
running the fan at over 50% motor speed. 
 

SPECIAL FEATURES 

 

IP rated box for speed controller and fused socket

 

 

IP65 rated for external use

 

 

Thermal overload protection 

 

Anti-vibration flexible connectors 

GENERAL 

 

Robust non-corrosive casing 

 

Ball bearing motor 

BENEFITS 

 

Easy to install

 

 

Low noise

 

 

Excellent for long duct runs

 

 

Can be installed horizontally or vertically

 

 
SAFETY RECOMMENDATIONS 

The fan conforms to the requirements according to 
the EU norms and directives. 
 
Precautions must be taken to avoid the back-flow of 
gases (gas spillage) into the room from open flues to 
gas appliances or open-fires.  This includes locations 
close to landfill sites (a methane test can be carried 
out to ascertain if installation is possible). 

 
Installation and connection of the fan should be done 
by skilled electricians in compliance with the relevant 
required documents. 
 
Do not carry out any maintenance or repairs to the 
fan unless the power supply has been disconnected.  
Prior to connecting the fan to the power supply it is 
necessary to make sure that there are no visible 
faults on the rotor, case, grid and that there are no 
foreign items in the airflow part of the case, which 
may damage the rotor blades. 

CAUTION:   

Do not use the fan in highly explosive environments. 
 

CONNECTION TO POWER SUPPLY 
(Speed controller diagram separate) 

1.

 

The fan must only be connected to single 
phase circuits 

2.

 

Make the wiring connections as indicated 
(Fig. 1) 

3.

 

The position of the fan must comply with the 
direction of the arrow on the fan casing. 

4.

 

Attach the brackets to the case. 

5.

 

Mount the fan to the wall using the anti-
vibration connectors. 

6.

 

Connect the fan to the pipe work using the 
rubber couplers supplied with the fan. 

 
PLEASE ENSURE THE CASING COVERING THE SPEED 
CONTROLLER IS PROPERLY SEALED AS WATER 
INGRESS CAN OCCUR AND WILL INVALIDATE ANY 
WARRANTY OR GUARANTEE. 
 
MAINTENANCE 

The power supply to the fan must be disconnected 
before any maintenance work is under taken. 

WARRANTY 

The UT150/SC has a three year warranty effective 
from the date of purchase, provided it has been 
installed according to the instructions supplied with 

the unit, it has not been connected to an unsuitable 
power supply and it has not been subjected to 
misuse.  If any part is found to be defective please 
contact your supplier/installer.  Return carriage is the 
responsibility of the buyer.  If it should become 
necessary to return a faulty unit please contact our 
office. 
 
 
Please provide the following information: 
 

Model Type:…………………………………………………………..

 

 
Voltag

e:……………………………………………….…….…………..

 

 

Date of Purchase:………………………………….…………..……

 

 

Invoice Number:……………………………………………………..

 

 
Fig 1 
   
 
 
 
 
 
 
 
 

Please note:  

the above information is for guidance only.  

If you have any queries regarding the above please 
contact us on our Helpline 01823 690290 
 
 
 
 
 
 
 
 