Why Doesn't the USRP Device Appear in the NI-USRP
Configuration Utility?
1.
Check the connection between the USRP device and the computer.
2.
Ensure that the USRP device is connected to a computer with a gigabit-compatible
Ethernet adapter.
3.
Ensure that a static IP address of
192.168.10.1
is assigned to the adapter in your
computer.
4.
Allow up to 15 seconds for the device to completely start up.
Why Don't NI-USRP Examples Appear in the NI Example Finder
in LabVIEW?
NI-USRP does not install examples into the NI Example Finder.
Related Information
Network Troubleshooting
Why Doesn't the Device Respond to a Ping
(ICMP Echo Request)?
The device should reply to an internet control message protocol (ICMP) echo request.
Complete the following steps to ping the device and receive a response.
1.
To ping the device, open a Windows command prompt and enter
ping
192.168.10.2
,
where
192.168.10.2
is the IP address for your USRP device.
2.
If you do not receive a response, verify that the host network interface card is set to a
static IP address corresponding to the same subnet as the IP address of the corresponding
device.
3.
Verify that the device IP address is set properly.
4.
Repeat step 1.
Related Information
on page 6
Why Doesn't the NI-USRP Configuration Utility Return a Listing
for My Device?
If the NI-USRP Configuration Utility does not return a listing for your device, search for a
specific IP address.
1.
Navigate to
<Program Files>\National Instruments\NI-USRP\
.
2.
<Shift>-right-click the
utilities
folder, and select
Open command window here
from the shortcut menu to open a Windows command prompt.