![National Instruments SCXI-1129 User Manual Download Page 54](http://html1.mh-extra.com/html/national-instruments/scxi-1129/scxi-1129_user-manual_3419569054.webp)
Chapter 2
Using the SCXI-1129
2-22
ni.com
Figure 2-14.
Cabling a DMM and Using Trig0–Trig7 to Bus the VMC/EXTRIG_1
to a Non-Cabled Module
The SCXI-1129 can accept trigger signals from any of the following
sources:
•
Rear signal connector
•
Front connector
•
Software trigger
•
Triggers 0–7
Note
Not all trigger lines are supported in all chassis. Make sure that the correct chassis
is chosen for your particular application.
Note
Trig0 - Trig7 refers to ttl0 - ttl7 in NI-SWITCH.
Hardware-Timed Scanning Using External
Instruments
When using the SCXI-1129 with an external measurement instrument, you
can use either synchronous or handshaking mode to advance though the
scan list.
Backplane
Connector
HVAB
RSC
Front Connector
Backplane
Connector
Front Connector
SCXI-1129
Backplane
Connector
Front Connector
SCXI-1129
Trig 0
Trig 1
Trig 6
Trig 7
•
•
•
From
DMM AUX
SCANADVD
SCANADVD
SCANADVD
Backplane
SCXI-1129