NI sbRIO-9601/9602/9602XT User Guide
16
ni.com
startup and disabling VIs from launching at startup, refer to the
Running a
Stand-Alone Real-Time Application (RT Module)
topic of the
LabVIEW
Help
.
USER1 Switch
You can define the USER1 switch for your application. To define the
purpose of this switch in your embedded application, use the RT Read
Switch VI in your LabVIEW RT embedded VI. For more information
about the RT Read Switch VI, refer to the
LabVIEW Help
.
NO FPGA Switch
Push the NO FPGA switch to the ON position to prevent a LabVIEW
FPGA application from loading at startup. The NO FPGA switch overrides
the options described in the
section. After startup you can
download bit files to flash memory from a LabVIEW project regardless of
switch position. If you already have an application configured to launch at
startup and you push the NO FPGA switch from ON to OFF, the startup
application is automatically enabled.
Using the Reset Button
Pressing the Reset button reboots the processor. The FPGA continues to
run unless you select the
Autoload VI on device reboot
boot option. Refer
to the
Understanding LED Indications
Figure 12.
NI sbRIO Device LEDs