5.9.4 Save <1..4>
This command saves the present state of the power supply to a specified location in memory
(refer to Table 5-7). Up to 4 states can be stored. Storage locations 1 through 4 are in nonvolatile
memory.
Save Front panel setting:
1. Press MENU button. MENU (green) LED illuminates. ”
set
” message appears on the Voltage
display.
2. Rotate Voltage encoder until ”
MEMO
” message appears on Voltage display.
3. Press Voltage encoder. ”
se
” message appears on Voltage display.
4. Press Voltage encoder. ”
SA e
” message appears on Voltage display. Numbers ”
1..4
” appear
on Current display.
5. Rotate the Current encoder to select required number value and then press the Current
encoder. Display blinks and returns to previous level.
5.9.5 Recall <1..4>
This command recalls the present state of the power supply from a specified location in memory
(refer to Table 5-7). Up to 4 states can be stored. Storage locations 1 through 4 are in nonvolatile
memory.
Recall front panel setting:
1. Press MENU button. MENU (green) LED illuminates. ”
set
” message appears on the Voltage
display.
2. Rotate the Voltage encoder until ”
MEMO
” message appears on Voltage display.
3. Press Voltage encoder. ”
ReC
” message appears on Current display.
4. Press Current encoder. Numbers ”
1..4
” appear on Current display.
5. Rotate the Current encoder to select required number value and then press the Current
encoder. Display blinks and returns to previous level.