RMX-4104 Series Specifications
RMX-4104
INPUT CHARACTERISTICS
20-40
36-24
60-14
100-8
1. Input voltage/freq. (*3)
---
85~265Vac continuous, 47~63Hz, single phase
2. Maximum Input current 100/200VAC (*4)
---
9.65/4.75
10.30/5.10
10.00/4.95
9.50/4.7
3. Power Factor (Typ)
---
0.99 at 100Vac, 100% load / 0.98 at 200Vac, 100% load
4. Efficiency (Typ) 100/200VAC (*4)
%
84/86
85/87
85/87
85/87
5. Inrush current (*5)
---
Less than 30A
ENVIRONMENTAL CONDITIONS
1. Operating temperature
---
0~50°C, 100% load.
2. Storage temperature
---
-20~85°C
3. Operating humidity
%
20~90% RH (no condensation).
4. Storage humidity
%
10~95% RH (no condensation).
5. Altitude
---
Maximum 3000m.
From 2000m up to 3000m, max. Ambient temperature 40°C and rated output current according to the table below:
20-40
36-24
60-14
100-8
Rated output current at 100≤V
in
≤265Vac
A
40
24
14
8
Rated output current at 85≤V
in
<100Vac
A
36
20
12.5
7.5
SAFETY/EMC
1. Applicable standards:
Safety
---
UL61010-1, EN61010-1, IEC61010-1. Design to meet UL60950-1, EN60950-1
10V≤Vout≤60V: Output,J1,J2,J3,J4,USB,LAN, are Non Hazardous
Vout=100V:Output,J1,J2 are Hazardous J3,J4,USB,LAN are Non Hazardous
EMC
---
IEC/EN61326-1 (Built to meet EN55022/EN55024)
2. Withstand voltage
---
10≤Vout≤36V models: Input-Output&J1,J2,J3,J4,USB,LAN/ 4242VDC/1min; Input-Ground: 2828VDC/1min.
Output&J1,J2,J3,J4,USB,LAN/Ground: 707VDC/1min.
60V,100V models: Input-Output&J1,J2: 4242VDC/1min; Input-J3,J4,USB,LAN/ 4242VDC/1min; Input-Ground: 2828VDC/1min. Output & J1,J2-
J3,J4,USB,LAN/1910VDC/1min; Output&J1,J2-Ground: 1380VDC/1min.
J3, J4, USB/LAN/ Ground: 707VDC/1min;
3. Insulation resistance
---
More than 100Mohm at 25°C, 70%RH.
4. Conducted emission
---
IEC/EN61326-1 Industrial Location - B, FCC part 15-B, VCCI-B
5. Radiated emission
---
IEC/EN61326-1 Industrial Location - A, FCC part 15-A, VCCI-A
MECHANICAL
1. Cooling
---
Forced air cooling by internal fan
2. Weight
STANDARD
Kg
Less than 2.1Kg.
3. Dimensions (WxHxD)
STANDARD
mm
H: 83, W: 70, D: 350 (excluding bus bars, handles…). (Refer to Outline drawing)
NOTES:
*1: Minimum voltage is guaranteed to maximum 0.1% of rated output voltage.
*2: Minimum current is guaranteed to maximum 0.2% of rated output current.
*3: For cases where conformance to various safety standards (UL, IEC, etc…) is required, to be described as 100-240Vac (50/60Hz).
*4: Ta=25°C with rated output power.
*5: Not including EMI filter inrush current, less than 0.2mSec.
*6: At 85~132Vac or 170~265VAC, constant load.
*7: From No-Load to Full-Load, constant input voltage. Measured at the sensing point in Remote Sense.
Summary of Contents for RMX-410 Series
Page 1: ...RMX 4101...
Page 30: ...29 NATIONAL INSTRUMENTS 2 4 1 Rackmount Dimensions Fig 2 3...
Page 128: ...127 NATIONAL INSTRUMENTS...
Page 130: ...NOTES...
Page 131: ...NOTES...
Page 132: ...NOTES...