104
NATIONAL
INSTRUMENTS
LIST:CURRent
Specifies the output current points in a list. The current points are given in the command parameters,
which are separated by commas.
SCPI Command Syntax
[SOURce]:LIST:CURRent <NRf+> {,<NRf+>}
Default Suffix
A
Examples
LIST:CURR 2.5,3.0,3.5 LIST:CURR MAX,2.5,MIN
up to 12 parameters
Query Syntax
LIST:CURRent?
Returned Parameters
2.5,3.0,3.5
LIST:LOAD
Loads from memory LIST type. Type voltage/current values, dwell values, STEP parameter and
counter specified in stored numbers <1..4>
SCPI Command Syntax
[SOURce]LIST:LOAD <NR1>
Examples
LIST:LOAD 3
LIST:DWELl
Specifies the time interval that each value (point) of a list is to remain in effect.
SCPI Command Syntax
[SOURce]:LIST:DWELI <NRf+> {,<NRf+>}
Range
0.001 to 129,600 seconds
Default Suffix
S
Examples
LIST:DWEL .6,1.5,1.5,.4
up to 12 parameters
Related Commands
CURR:MODE LIST:COUN LIST:CURR LIST:STEP
LIST:VOLT VOLT:MODE
Query Syntax
LIST:DWEL?
Returned Parameters
.6,1.5,1.5,.4
LIST:STEP
Determines if a trigger causes a list to advance only to its next point or to sequence through all
the points.
• LIST:STEP AUTO - When triggered, it creates waveforms consecutively, until the list is
completed.
• LIST:STEP ONCE - When triggered, it executes one step from the list.
SCPI Command Syntax
[SOURce]:LIST:STEP <CRD>
Parameters
AUTO | ONCE
*RST
AUTO
Examples
LIST:STEP ONCE
Query Syntax
[SOURce]:LIST:STEP?
Returned Parameters
AUTO | ONCE