Figure 10. Rotary Encoding Switch
0
2
4
6
8
9
x1
S2
0
2
4
6
8
10
12
14
x10
S1
After setting the rotary switches, restart the REM-11180 to update the address assignment.
Note
NI EtherCAT master does not support the rotary encoding switch on the
REM-11180.
Restoring Default Settings
To restore the REM-11180 to default settings, follow these steps:
1.
Disconnect power to the REM-11180.
2.
Press and hold the reset button.
3.
Power on the REM-11180.
4.
Release the button when the RDY LED flashes red and green.
Reading Error Codes from REM-11180 IOVs
When you add the REM-11180 to the RT Target in the LabVIEW project, the following IOVs
are available:
Table 6. LabVIEW Project IOVs for Remote I/O Systems
IOV
Data Type
Purpose
Localbus Add_Error
Info
U16
Indicates which I/O module is returning an error.
Localbus bus State
U16
Returns the current bus state. Refer to the
Diagnostic
Status Register
table for more information.
REM-11180 User Manual
|
© National Instruments
|
9