![National Instruments PXIe-8830mc User Manual Download Page 7](http://html1.mh-extra.com/html/national-instruments/pxie-8830mc/pxie-8830mc_user-manual_3685770007.webp)
and various other types of instruments. This API aids in the creation of portable applications
and instrument drivers. For information about writing your own PXI Express instrument driver
with NI-VISA, refer to the
NI-VISA Getting Started Manual
and the
readme.txt
file in the
NI-VISA directory. For more information, visit
ni.com/visa
.
With LabVIEW for Linux and support for more than two hundred devices on Linux with the
NI-DAQmx driver, you now can create Virtual Instruments based on the Linux OS. The NI-
VISA driver for Linux has improved instrument control in Linux, and NI Modular Instruments
are partially supported. For more information, visit
ni.com/linux
.
Configuration
System CMOS
The NI PXIe-8830mc contains memory backed up by a battery to store BIOS configuration
information.
Complete the following steps to clear the CMOS contents:
1.
Power off the chassis.
2.
Remove the processor module from the chassis.
3.
Press the push-button switch, as shown in the following figure.
4.
Wait 10 seconds.
5.
Reinstall the processor module in the chassis.
NI PXImc Devices User Manual
|
© National Instruments
|
7