![National Instruments PXIe-8830mc User Manual Download Page 11](http://html1.mh-extra.com/html/national-instruments/pxie-8830mc/pxie-8830mc_user-manual_3685770011.webp)
Power Requirements
Power Rail
Typical Current
Maximum Current
+3.3 V
1450 mA
2180 mA
+12 V
3750 mA
3940 mA
+5 V
Aux
70 mA
110 mA
Note:
Does not include any attached USB devices.
Environment
............................................................................
Maximum altitude
2,000 m (800 mbar)
............................................................................
Pollution Degree
2
Indoor use only.
Operating Environment
............................................................................
Ambient temperature range
(maximum performance)
0 to 40 °C
............................................................................
Ambient temperature range
0 to 55 °C (Tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3 low temperature
limit and MIL-PRF-28800F Class 2 high
temperature limit.)
............................................................................
Relative humidity range
10 to 90%, noncondensing (Tested in
accordance with IEC-60068-2-56.)
Storage Environment
............................................................................
Ambient temperature range
-40 to 71 °C (Tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3 limits.)
............................................................................
Relative humidity range
5 to 95%, noncondensing (Tested in
accordance with IEC-60068-2-56.)
Shock and Vibration
............................................................................
Operational shock
30 g peak, half-sine, 11 ms pulse (Tested in
accordance with IEC-60068-2-27. Meets MIL-
PRF-28800F Class 2 limits.)