Electromagnetic Compatibility Guidelines

This product was tested and complies with the regulatory requirements and limits for
electromagnetic compatibility (EMC) stated in the product specifications. These requirements
and limits provide reasonable protection against harmful interference when the product is
operated in the intended operational electromagnetic environment.

This product is intended for use in industrial locations. However, harmful interference may
occur in some installations, when the product is connected to a peripheral device or test object,
or if the product is used in residential or commercial areas. To minimize interference with
radio and television reception and prevent unacceptable performance degradation, install and
use this product in strict accordance with the instructions in the product documentation.

Furthermore, any changes or modifications to the product not expressly approved by National
Instruments could void your authority to operate it under your local regulatory rules.

Caution

 

To ensure the specified EMC performance, operate this product only with

shielded cables and accessories connected to the LO/Sense LO, Output HI, and
Sense HI connectors. Only twisted, shielded pair cable (i.e. Belden 83321E) should
be used to connect the signals of the LO/Sense LO connector. Any compatible
unshielded twisted-pair cable may be used for the safety interlock connector.

Caution

 

To ensure the specified EMC performance, the length of all I/O cables

must be no longer than 3 m (10 ft).

Safety Guidelines for Hazardous Voltages

If hazardous voltages are connected to the device, take the following precautions. A hazardous
voltage is a voltage greater than 42.4 Vpk voltage or 60 VDC to earth ground.

Caution

 

This module is rated for Measurement Category I. It is intended to carry

signal voltages no greater than 250 V DC. This module can withstand up to
500 V DC impulse voltage. Do not use this module for connection to signals or for
measurements within Categories II, III, or IV. Do not connect to MAINS supply
circuits (for example, wall outlets) of 115 V AC or 230 V AC.

Caution

 

Isolation voltage ratings apply to the voltage measured between any

channel pin and the chassis ground. When operating channels in series or floating on
top of external voltage references, ensure that no terminal exceeds this rating.

Verifying the System Requirements

To use the NI-DCPower instrument driver, your system must meet certain requirements.

2

  | 

ni.com

  | 

PXIe-4135 Getting Started Guide

Summary of Contents for PXIe-4135

Page 1: ...the product is damaged return it to NI for repair Contents Electromagnetic Compatibility Guidelines 2 Safety Guidelines for Hazardous Voltages 2 Verifying the System Requirements 2 Unpacking the Kit 3...

Page 2: ...sories connected to the LO Sense LO Output HI and Sense HI connectors Only twisted shielded pair cable i e Belden 83321E should be used to connect the signals of the LO Sense LO connector Any compatib...

Page 3: ...unding strap or by holding a grounded object such as your computer chassis 1 Touch the antistatic package to a metal part of the computer chassis 2 Remove the device from the package and inspect the d...

Page 4: ...tems not included in your device kit that you need to operate the PXIe 4135 Your application may require additional items not included in your kit to install or operate your device Required Items A PX...

Page 5: ...ree 2 Indoor use only Note Refer to the device specifications on ni com manuals for complete specifications Installing the Software You must be an Administrator to install NI software on your computer...

Page 6: ...that it is properly connected to safety ground Ensure that the PXIe 4135 is properly secured to the chassis using the two front panel mounting screws Double insulate all electrical connections that a...

Page 7: ...ed in series so that a single switch failure does not compromise safety protections Isolate switches so the operator cannot trigger or bypass the switches without the use of a tool Ensure the switches...

Page 8: ...talling the PXIe 4135 Caution To prevent damage to the PXIe 4135 caused by ESD or contamination handle the module using the edges or the metal bracket 1 Ensure the AC power source is connected to the...

Page 9: ...e 11 Cover all empty slots using EMC filler panels or fill using slot blockers to maximize cooling air flow depending on your application 12 Prepare the LO Sense LO connector assembly Caution To ensur...

Page 10: ...ngth for the safety interlock cable is 7 5 mm 0 295 in minimum and 10 mm 0 394 in absolute maximum The acceptable AWG range for the safety interlock cable is 16 24 b Use an insulation strip tool to ex...

Page 11: ...l ACCESS VOLTAGE LO HI GUARD GUARD INT PASS THRU SENSE LO SENSE HI SAFETY INTERLOCK 3 3 V MAX OUTPUT 200 V 1 A 3 A Pulse MAX 250 V MAX to PXIe 4135 Precision System SMU A C D E B K M J L F H I G PXIe...

Page 12: ...ries Table 2 PXIe 4135 Accessories Accessory Manufacturer Part Number Additional Connector Kit with Interlock Connector for PXIe 4135 SMU NI 784484 01 Safety Interlock Connector Phoenix Contact 179029...

Page 13: ...sure that the safety interlock input on the test fixture is closed 3 Set the niDCPower Output Function property or NIDCPOWER_OUTPUT_FUNCTION attribute to DC Voltage for the PXIe 4135 4 Set the voltage...

Page 14: ...tatus Indicator is red and that a hazardous voltage error message appears 11 On the error message dialog click OK to prompt the PXIe 4135 to attempt to clear the error and re initialize the session to...

Page 15: ...quisition and measurement options using LabVIEW VIs or LabWindows CVI functions C or LabWindows CVI Available at Program Files IVI Foundation IVI Drivers NI DCPower Microsoft Visual C C NI DCPower doe...

Page 16: ...st with the PXI Express power rails a hardware module or the LED 1 Caution Apply external signals only while the PXIe 4135 is powered on Applying external signals while the module is powered off may c...

Page 17: ...te is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application development self help resources to email and phone assistance fr...

Page 18: ...oducts technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents You can find informatio...

Reviews: