Chapter 2
Installation, Configuration, and Operation
©
National Instruments Corporation
2-5
Connecting to Power Source
Attach input power through the rear AC inlet using the appropriate line
cord supplied. Refer to Figure 1-2,
Rear View of the PXI-1025 MegaPAC
, for a diagram of the IEC 320 inlet.
Push the power switch to the On position (if not already on). Observe
that all fans become operational.
If the chassis fails to power up, refer to the following table for possible
causes for the power failure and ways to correct them.
Installing PXI Modules
Caution
Turn off the chassis power before installing CompactPCI or PXI modules.
Install a module into a chassis slot by first placing the module’s card edges
into the front module guides (top and bottom), as shown in Figure 2-3.
Slide the module into the chassis (making sure that the injector/ejector
handle is pushed down as shown in Figure 2-4.
When you begin to feel resistance, push up on the injector/ejector handle
to inject the card into the frame. Secure the module’s front panel to the
chassis using the module’s front-panel mounting screws.
Table 2-1.
Power Supply Troubleshooting
Possible Cause
What to Do
Faulty module installed in chassis.
Remove all modules from the chassis and check
power again.
PXI-1025 MegaPAC chassis is not connected to
power source.
Make sure that the PXI-1025 MegaPAC is
connected to a live electrical outlet. Try
operating another piece of equipment from
this outlet.
Power switch is not switched on.
Set the power switch to the On (1) position.
Power supply has failed.
Contact National Instruments.