This document provides the installation procedure for the NI PS-14/15/16/17 Side Mount 
Brackets. This accessory is used to mount NI PS-14/15/16/17 power supplies sideways to reduce 
the installation depth.

Two side mounting options are possible:

35 mm DIN-Rail Mount

Panel Mount

Bracket and Assembly Dimensions

This section provides bracket and assembly dimensions. Table 1 provides a summary of the 
dimensions and weight of the overall assembly when a specific bracket set is mounted to a 
specific power supply. The 

Unit

 column lists the available power supplies. The 

Bracket Set 

column indicates the appropriate brackets to use with the specified power supply. The 

A

 column 

provides dimensions from the front of the power supply to the rearmost mounting screw for the 
assembly of power supply and brackets. The 

B

column provides the total installation depth of 

the assembly when mounted. The 

C

column provides the depth of the power supply only. The 

Length

 column provides the total length of the assembly. The 

Width

 column provides the width 

of the mounting brackets. The 

Height

 column provides the height of the brackets only. The 

Bracket Set Weight

 column provides the weight of the bracket set only.

Table 1.  

Bracket Set and Assembly Dimensions and Weight

Units

Use 

Bracket 

Set

A

B

*

C

Length

Width

Height

Bracket 

Set 

Weight

NI PS-14

199429-01

89 mm

38 mm

32 mm

145 mm

65 mm

37 mm

140 g

NI PS-15

199429-01

104 mm

38 mm

32 mm

145 mm

65 mm

37 mm

140 g

NI PS-16

199430-01

104 mm

66 mm

60 mm

145 mm

65 mm

63 mm

180 g

NI PS-17

199431-01

124 mm

88 mm

82 mm

145 mm

65 mm

84.5 mm

205 g

*

 If the unit is panel mounted, the B dimension shows the required installation depth. If the unit is DIN-Rail 

mounted, the total installation depth is the B dimension plus 6 mm plus the height of the DIN-Rail.

Summary of Contents for PS-15

Page 1: ...the assembly of power supply and brackets The B column provides the total installation depth of the assembly when mounted The C column provides the depth of the power supply only The Length column pr...

Page 2: ...wer supply Figure 1 Physical Dimension Variables Figure 2 provides the B and C variables for determining the depth of a bracketed power supply assembly when mounting the assembly to a DIN Rail or pane...

Page 3: ...keted power supply mounted to a DIN Rail Figure 3 Calculating the Dimensions for Screw Mounts Assembly and Mounting Instructions This section provides instructions for mounting the power supply sidewa...

Page 4: ...ation Guide Sideways Panel Mounting Complete the following steps to mount the brackets to a flat wall 1 Detach the two aluminium brackets by removing the four screws with a Torx 10 screwdriver as show...

Page 5: ...ock mechanism with a flathead screwdriver to move the lock downward while at the same time pushing the plastic slider upwards Detach the plastic slider as shown in Figure 5 Figure 5 Removing the Plast...

Page 6: ...igure 6 Mounting the Steel Brackets DIN Rail Mounting Complete the following steps to mount the brackets to a DIN Rail 1 Install the mounting plate with the steps described in the Sideways Panel Mount...

Page 7: ...m services for NI Factory Installation Services repairs extended warranty and other services Visit ni com register to register your National Instruments product Product registration facilitates techni...

Page 8: ...nstruments products technology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patents Notice at ni com patents You can f...

Reviews: