Getting Started with the NI CVS-1450 Series 

IEEE 1394

Number of ports .....................................................3

Camera interface ....................................................IEEE 1394a

Speed......................................................................100, 200, or 400 Mbps

Available bus power ...............................................Refer to th

Power Requirements

 section

Physical Characteristics

Dimensions ............................................................10.2 cm 

×

 12.7 cm 

×

 6.4 cm 

(4 in. 

×

 5 in. 

×

 2.5 in.)

Weight ....................................................................1 kg (2.2 lb)

Refer to Appendix B, 

Mounting Information

, of the 

NI CVS-1450 Series User Manual

 for dimensional 

drawings of the NI CVS-1450 device.

Environmental

The NI CVS-1450 device is intended for indoor use only.

Operating temperature

Vertical mounting position.............................0 to 55 °C

All other positions..........................................0 to 45 °C

Storage temperature ...............................................–20 to 85 °C 

Humidity ................................................................10 to 90% RH, noncondensing

Pollution Degree ....................................................2

Operating shock (IEC 68-2-27) .............................50 g, 6 ms half sine, 3 shocks per side; 

30 g 11 ms half sine, 3 shocks per side

Operating vibration

Random (IEC 60068-2-34) ............................10 to 500 Hz, 5 G

rms

Swept Sine (IEC 60068-2-6)..........................10 to 500 Hz, 5 g

Approved at altitudes up to 2,000 m.

Safety

The NI CVS-1450 device meets the requirements of the following standards for safety and electrical 
equipment for measurement, control, and laboratory use:

EN 61010-1, IEC 61010-1

UL 61010-1

CAN/CSA-C22.2 No. 61010-1

Note

For UL and other safety certifications, refer to the product label or visit 

ni.com/

certification

, search by model number or product line, and click the appropriate link the 

Certification column.

Summary of Contents for NI Vision CVS-1450 Series

Page 1: ...0 Series compact vision system Development computer running Windows Vista XP 2000 DCAM compliant IEEE 1394 camera IEEE 1394 jackscrew to latch cable part number 778796 01 or any standard IEEE 1394 cab...

Page 2: ...stalling and operating the device Do not operate the device in a manner not specified in the documentation Misuse of the device may result in a hazard and may compromise the safety protection built in...

Page 3: ...em referred to as MAINS4 voltage This category is for measurements of voltages from specially protected secondary circuits Such voltage measurements include signal levels special equipment limited ene...

Page 4: ...ra and a monitor to the NI CVS 1450 device refer to Figure 2 while completing the following steps 1 Connect the VGA cable from the monitor to the VGA port on the NI CVS 1450 device 2 Plug the IEEE 139...

Page 5: ...connect power to the NI CVS 1450 device refer to Figure 3 while completing the following steps 1 Plug the 4 position connector from the power supply into the power receptacle on the NI CVS 1450 devic...

Page 6: ...e the wires leading to the 4 position power connector as shown in Figure 4 Ferrules are available from Phoenix Contact part number 3200519 Figure 4 Wiring a Third Party Power Supply to the 4 Position...

Page 7: ...ment computer and the NI CVS 1450 device directly using a CAT 5 or CAT 6 Ethernet crossover cable Caution To prevent data loss and to maintain the integrity of your Ethernet installation do not use a...

Page 8: ...teps to install LabVIEW the LabVIEW Real Time Module the NI Vision Development Module and NI Vision Acquisition Software onto the development computer Note You must install LabVIEW the LabVIEW Real Ti...

Page 9: ...special characters except hyphens The first and last characters must be alphanumeric 4 If the network is configured to issue IP addresses using DHCP select Obtain IP address from DHCP server Otherwis...

Page 10: ...Select the Existing target or device option from Targets and Devices expand the Compact Vision System branch select your device and click OK 9 Click Next 10 Verify that the NI CVS 1450 device appears...

Page 11: ...CVS 1456 256 MB Processor NI CVS 1454 Intel Celeron 400 MHz processor NI CVS 1455 Intel Celeron 650 MHz processor NI CVS 1456 Intel Celeron 733 MHz processor Network Network interface 10BaseT and 100...

Page 12: ...13 Input voltage range 0 to 30 V Input ON voltage 3 5 to 30 V Input OFF voltage 0 to 2 V Turn on current 7 1 mA typical 14 mA maximum Maximum pulse rate 100 kHz Minimum pulse detected 10 s Reverse pol...

Page 13: ...All other positions 0 to 45 C Storage temperature 20 to 85 C Humidity 10 to 90 RH noncondensing Pollution Degree 2 Operating shock IEC 68 2 27 50 g 6 ms half sine 3 shocks per side 30 g 11 ms half si...

Page 14: ...product line and click the appropriate link in the Certification column Environmental Management National Instruments is committed to designing and manufacturing products in an environmentally respon...

Page 15: ...also has offices located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and follow the calling instructio...

Page 16: ...nal Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the...

Reviews: