background image

©

 National Instruments Corporation

11

Getting Started with the NI CVS-1450 Series 

Specifications

The following specifications apply to the NI CVS-1450 device. These specifications are typical at 
25 °C, unless otherwise stated.

Power Requirements

Main supply voltage...............................................24 VDC ±10%

Power (excluding cameras)............................12 W, typical

22 W, maximum

IEEE 1394 bus power ....................................18 W, maximum

(shared by all three ports)

Isolated supply

1

......................................................5 to 30 VDC

Memory

SDRAM .................................................................128 MB

Nonvolatile storage

NI CVS-1454 .................................................64 MB

NI CVS-1455 .................................................128 MB

NI CVS-1456 .................................................256 MB

Processor

NI CVS-1454 .........................................................Intel Celeron 400 MHz processor

NI CVS-1455 .........................................................Intel Celeron 650 MHz processor

NI CVS-1456 .........................................................Intel Celeron 733 MHz processor

Network

Network interface...................................................10BaseT and 100BaseTX Ethernet

Compatibility .........................................................IEEE 802.3

Maximum cabling distance ....................................100 m/segment

TTL Inputs and Outputs

Digital logic levels

1   

Do 

not

 draw more than 500 mA combined from the Viso pins on the 44-pin DSUB connector. Do 

not

 draw more than 100 mA 

from 24V or 30V isolated outputs. Do 

not 

draw more than 50 mA from 5V isolated outputs.

Level

Minimum

Maximum

Input low voltage (V

IL

)

0 V

0.5 V

Input high voltage (V

IH

)

2.2 V

5 V

Output low voltage (V

OL

), at 5 mA

0.4 V

Output high voltage (V

OH

), at 5 mA

2.4 V

Summary of Contents for NI Vision CVS-1450 Series

Page 1: ...0 Series compact vision system Development computer running Windows Vista XP 2000 DCAM compliant IEEE 1394 camera IEEE 1394 jackscrew to latch cable part number 778796 01 or any standard IEEE 1394 cab...

Page 2: ...stalling and operating the device Do not operate the device in a manner not specified in the documentation Misuse of the device may result in a hazard and may compromise the safety protection built in...

Page 3: ...em referred to as MAINS4 voltage This category is for measurements of voltages from specially protected secondary circuits Such voltage measurements include signal levels special equipment limited ene...

Page 4: ...ra and a monitor to the NI CVS 1450 device refer to Figure 2 while completing the following steps 1 Connect the VGA cable from the monitor to the VGA port on the NI CVS 1450 device 2 Plug the IEEE 139...

Page 5: ...connect power to the NI CVS 1450 device refer to Figure 3 while completing the following steps 1 Plug the 4 position connector from the power supply into the power receptacle on the NI CVS 1450 devic...

Page 6: ...e the wires leading to the 4 position power connector as shown in Figure 4 Ferrules are available from Phoenix Contact part number 3200519 Figure 4 Wiring a Third Party Power Supply to the 4 Position...

Page 7: ...ment computer and the NI CVS 1450 device directly using a CAT 5 or CAT 6 Ethernet crossover cable Caution To prevent data loss and to maintain the integrity of your Ethernet installation do not use a...

Page 8: ...teps to install LabVIEW the LabVIEW Real Time Module the NI Vision Development Module and NI Vision Acquisition Software onto the development computer Note You must install LabVIEW the LabVIEW Real Ti...

Page 9: ...special characters except hyphens The first and last characters must be alphanumeric 4 If the network is configured to issue IP addresses using DHCP select Obtain IP address from DHCP server Otherwis...

Page 10: ...Select the Existing target or device option from Targets and Devices expand the Compact Vision System branch select your device and click OK 9 Click Next 10 Verify that the NI CVS 1450 device appears...

Page 11: ...CVS 1456 256 MB Processor NI CVS 1454 Intel Celeron 400 MHz processor NI CVS 1455 Intel Celeron 650 MHz processor NI CVS 1456 Intel Celeron 733 MHz processor Network Network interface 10BaseT and 100...

Page 12: ...13 Input voltage range 0 to 30 V Input ON voltage 3 5 to 30 V Input OFF voltage 0 to 2 V Turn on current 7 1 mA typical 14 mA maximum Maximum pulse rate 100 kHz Minimum pulse detected 10 s Reverse pol...

Page 13: ...All other positions 0 to 45 C Storage temperature 20 to 85 C Humidity 10 to 90 RH noncondensing Pollution Degree 2 Operating shock IEC 68 2 27 50 g 6 ms half sine 3 shocks per side 30 g 11 ms half si...