![National Instruments NI sbRIO-960x User Manual Download Page 17](http://html1.mh-extra.com/html/national-instruments/ni-sbrio-960x/ni-sbrio-960x_user-manual_709037017.webp)
©
National Instruments Corporation
17
NI sbRIO-960x
Using the Reset Button
Pressing the Reset button reboots the processor. The FPGA continues to
run unless you select the
Autoload VI on Device Reboot
boot option.
Refer to the
section for more information.
Understanding LED Indications
Figure 11.
sbRIO-960
x
LEDs
FPGA LED
You can use the FPGA LED to help debug your application or easily
retrieve application status. Use the LabVIEW FPGA Module and NI-RIO
software to define the FPGA LED to meet the needs of your application.
Refer to
LabVIEW Help
for information about programming this LED.
USER LED
You can define the USER LED to meet the needs of your application. To
define the LED, use the RT LEDs VI in LabVIEW. For more information
about the RT LEDs VI, refer to the
LabVIEW Help
.
POWER LED
The POWER
LED is lit while the sbRIO device is powered on. This LED
indicates that the 5 V and 3.3 V rails are stable.
STATUS LED
The STATUS LED is off during normal operation. The sbRIO device
indicates specific error conditions by flashing the STATUS LED a certain
number of times as shown in Table 4.
1
FPGA
2
U
S
ER
3
POWER
4
S
TATU
S
3
1
4
2