Specifications
©
National Instruments Corporation
A-9
NI PXI-6682 Series User Manual
Environmental
Operating Environment
Ambient temperature range.................... 0 to 55 °C
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2.)
Relative humidity range ......................... 10% to 90%, noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Maximum altitude .................................. 2,000 m (at 25 °C ambient
temperature)
Pollution Degree .................................... 2
Indoor use only.
Storage Environment
Ambient temperature range.................... –20 to 70 °C
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2.)
Relative humidity range ......................... 5% to 95% noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Shock and Vibration
Operational Shock.................................. 30 g peak, half-sine, 11 ms pulse
(Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.)