background image

Getting Started with the NI PCIe-8255R

6

ni.com

Figure 2.  

NI 8255R Connectors

9.

Replace the computer cover.

10. Connect the IEEE 1394 cable to your camera. Refer to your camera manufacturer documentation 

for specific instructions about how to connect the cable to your camera.

11. Connect the IEEE 1394 cable to an IEEE 1394 connector on the NI 8255R front panel. 

12. Plug in and power on the computer.

The NI 8255R is now installed and the camera is connected.

Wiring Isolated Output Power to the NI 8255R

Complete the following steps to connect power for the isolated outputs to the NI 8255R.

Caution

Do 

not

 connect the NI 8255R isolated power to a source less than 5 VDC or greater than 

30 VDC. Doing so could damage the device.

1.

Complete this step if you are using the NI desktop power supply (part number 778794-01). If you 
are using a power supply other than the NI desktop power supply skip this step and proceed to 
step 2.

a.

Disconnect the 4-position power connector from the power supply, as shown in Figure 3.

1

IEEE 1394b Bilingual Connector

2

ISO/ATX Power Status LEDs

3

IEEE 1394b Bilingual Connector

4

44-Pin D-SUB Connector

5

Camera Power ATX Connector

NI PCIe-8255R

FOR PATENTS: NI.COM/PATENTS

1

2

3

4

5

Summary of Contents for NI PCIe-8255R

Page 1: ...and NI IMAQ I O driver software Optional software for developing applications NI Vision Development Module NI Vision Builder for Automated Inspection LabVIEW LabWindows CVI Microsoft Visual Basic Opti...

Page 2: ...esult in a hazard and may compromise the safety protection built into the device If the device is damaged turn it off and do not use it until service trained personnel can check its safety If necessar...

Page 3: ...to as MAINS4 voltage This category is for measurements of voltages from specially protected secondary circuits Such voltage measurements include signal levels special equipment limited energy parts o...

Page 4: ...s for the NI 8255R 1 Install NI Vision Acquisition Software before installing the NI 8255R Refer to the NI Vision Acquisition Software Release Notes for specific installation instructions 2 Power off...

Page 5: ...e aligns up with the hole in the back panel rail of the computer chassis 7 Secure the device mounting bracket to the back panel rail of the computer 8 To provide power to your camera connect an unused...

Page 6: ...plete the following steps to connect power for the isolated outputs to the NI 8255R Caution Do not connect the NI 8255R isolated power to a source less than 5 VDC or greater than 30 VDC Doing so could...

Page 7: ...If you are using the NI desktop power supply skip this step and proceed to step 3 a Wire the voltage output and the common mode ground output of the isolated power supply to one of the following optio...

Page 8: ...e when the computer is on and an isolated power supply is properly connected Configuring the NI 8255R After you have installed the NI 8255R and powered on the computer the computer will recognize the...

Page 9: ...ge 0 V to 5 V Maximum pulse rate 2 MHz Optically Isolated Inputs and Outputs Isolated Current Sinking Inputs Number of channels 13 Input voltage range 0 V to 30 V Input ON voltage 3 5 V to 30 V Input...

Page 10: ...6 in Weight 130 g 4 5 oz Environment The NI 8255R is intended for indoor use only Operating temperature 0 C to 55 C Storage temperature 20 C to 70 C Relative humidity 5 to 90 noncondensing Pollution D...

Page 11: ...ions Group 1 Class A CE C Tick ICES and FCC Part 15 Emissions Class A Note For EMC compliance operate this device according to product documentation CE Compliance This product meets the essential requ...

Page 12: ...ts calibration you can obtain the calibration certificate for your product at ni com calibration National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 787...