28 | ni.com | NI EDIDS-2400 Series User Manual
3.2.3.3 Manually Resetting The
Controller Network Interface To DHCP
This section assumes that all attempts have failed to establish connection with the DI Driver System user interface,
and the system controller IP address is unknown.
Before resetting the controller network settings to DHCP mode, consider the
following:
1. Reboot the System Controller
Press and release the reset button on the front of the
controller. Wait about 1 minute for both the
USER1 and USER FPGA LEDs to start blinking. The typical time to start blinking is about 25 seconds. A
connection cannot be established with the user interface via SCM until both User LEDs are blinking. If both
LEDs are not blinking, refer to the
section.
If the IP address of the controller is discovered via the Search for SCM Target... dialog, but the Download
Files checkbox does not appear in the dialog, then take note of the discovered IP address. The Windows PC
used to interface with the system must have a similar IP address and Subnet mask as the system controller,
but the IP address must be different in the last address number. The Subnet mask should be 255.255.255.0.
section to see how to change the IP address of the Windows PC.
3. Use SCM Real-Time Target Backup Feature to Discover the IP Address
From the SCM console, select File, then
Real-Time Backup and Restore
to open the
Real-Time System
Backup
dialog. Select the
Backup Real-Time System
button to open the Backup Target dialog.
Select the
Browse button
to open the
Select RT System
dialog.
Summary of Contents for NI EDIDS-2400 Series
Page 2: ...2 ni com NI EDIDS 2400 Series User Manual...
Page 13: ...NI EDIDS 2400 Series User Manual National Instruments 13 3 2 Software...
Page 35: ...NI EDIDS 2400 Series User Manual National Instruments 35...
Page 43: ...NI EDIDS 2400 Series User Manual National Instruments 43 3 3 Hardware...
Page 48: ...48 ni com NI EDIDS 2400 Series User Manual 3 3 3 Connecting Injectors Sensors and Actuators...
Page 60: ...60 ni com NI EDIDS 2400 Series User Manual 3 3 5 b Side View of Optional Enclosure...
Page 86: ...86 ni com NI EDIDS 2400 Series User Manual See descriptions for PFI 1...
Page 241: ...NI EDIDS 2400 Series User Manual National Instruments 241 Aux PWX 2 4 See above descriptions...
Page 254: ...254 ni com NI EDIDS 2400 Series User Manual...
Page 268: ...268 ni com NI EDIDS 2400 Series User Manual...
Page 271: ...NI EDIDS 2400 Series User Manual National Instruments 271...
Page 294: ...294 ni com NI EDIDS 2400 Series User Manual...
Page 306: ...306 ni com NI EDIDS 2400 Series User Manual 22 TDK to cRIO Remote Connection...
Page 308: ...308 ni com NI EDIDS 2400 Series User Manual 8 Important Information...