Analog Comparison Event
•
Change Detection Event
A counter’s Internal Output can be routed to a different counter’s HW Arm.
Some of these options may not be available in some driver software. Refer to the "Device
Routing in MAX" topic in the
NI-DAQmx Help
or the
LabVIEW Help
for more information
about available routing options.
Counter n Sample Clock Signal
Use the Counter
n
Sample Clock (Ctr
n
SampleClock) signal to perform sample clocked
acquisitions and generations.
You can specify an internal or external source for Counter
n
Sample Clock. You also can
specify whether the measurement sample begins on the rising edge or falling edge of Counter
n
Sample Clock.
If the cRIO controller receives a Counter
n
Sample Clock when the FIFO is full, it reports an
overflow error to the host software.
Using an Internal Source
To use Counter
n
Sample Clock with an internal source, specify the signal source and the
polarity of the signal. The source can be any of the following signals:
•
DI Sample Clock
•
DO Sample Clock
•
AI Sample Clock
•
AI Convert Clock
•
AO Sample Clock
•
DI Change Detection output
Several other internal signals can be routed to Counter
n
Sample Clock through internal routes.
Refer to "Device Routing in MAX" in the
NI-DAQmx Help
or the
LabVIEW Help
for more
information.
Using an External Source
You can route any of the following signals as Counter
n
Sample Clock:
•
Any PFI terminal
•
Analog Comparison Event
You can sample data on the rising or falling edge of Counter
n
Sample Clock.
Routing Counter n Sample Clock to an Output Terminal
You can route Counter
n
Sample Clock out to any PFI terminal. The PFI circuitry inverts the
polarity of Counter
n
Sample Clock before driving the PFI terminal.
NI cRIO-905x User Manual
|
© National Instruments
|
99