background image

NI 9754 User Manual

|

© National Instruments

|

3

Powering the Module

The NI 9754 requires power from the CompactRIO backplane male high density D-SUB 15-pin 
(HD15) connector, which mates with the female HD15 connector on the NI 9754. This power 
source provides a regulated 5 V and ground to various digital logic functions within the NI 9754. 
The CompactRIO 5 V source is active whenever the CompactRIO or R Series Expansion 
Chassis is properly powered. You can power the NI 9754 only at the HD15 connector by 
plugging it into a CompactRIO or R Series Expansion Chassis.

Platform Compatibility

NI Powertrain Control modules require a hardware support system to function. You cannot use 
the modules independently or interfaced with third-party devices at the backplane HD15 
connector. NI Powertrain Control modules are compatible with the following National 
Instruments platforms:

CompactRIO, which consists of a CompactRIO controller, chassis, or integrated 
controller/chassis.

NI PXI, which consists of any NI PXI chassis, NI PXI RT controller, and NI PXI-78

xx

R Series FPGA card. The NI Powertrain Control modules insert into an NI R Series 
expansion chassis. Connect an NI R Series expansion chassis to the NI PXI FPGA card 
using a SHC68-68-RDIO cable.

Note

NI Powertrain Control modules are not compatible with the National 

Instruments CompactDAQ chassis.

You can use NI Powertrain Control modules with NI cRIO-911

x

, NI cRIO-907

x

, and NI R Series 

Expansion systems under the following conditions:

Leave one empty chassis slot between NI Powertrain Control modules and other 
NI modules.

Maintain an ambient system operating temperature of 0 °C to 45 °C.

Note

Typical specifications of National Instruments modules might not apply when 

used in a system with NI Powertrain Control modules. 

Note

National Instruments guarantees warranted specifications for all National 

Instruments modules except thermocouple modules when used in a system with 
NI Powertrain Control modules.

Note

National Instruments recommends the NI 9214 for thermocouple 

measurements in CompactRIO systems using NI Powertrain Control modules.

Note

NI Powertrain Control modules do not support Scan Interface mode, 

auto-detection, or ID mode. 

Summary of Contents for NI 9754

Page 1: ... Engine Synchronous TTL Output Module Contents Introduction 2 Pinout 2 Powering the Module 3 Platform Compatibility 3 ESTTL Outputs 4 Digital Output Characteristics 4 Physical Specifications and Characteristics 4 Compliance and Certifications 5 ...

Page 2: ...cuits Features Sends commands to external custom driver circuits or smart actuators with built in driver circuits 200 ns output resolution 8 channel TTL output LabVIEW FPGA support for high speed engine synchronous multi pulse fuel or spark control Pinout Figure 1 NI 9754 Pin Assignments COM NC COM COM NC COM COM NC COM COM NC COM COM DO 0 NC DO 1 DO 2 NC DO 3 DO 4 NC DO 5 DO 6 NC DO 7 1 2 3 4 5 6...

Page 3: ... NI PXI chassis NI PXI RT controller and NI PXI 78xxR R Series FPGA card The NI Powertrain Control modules insert into an NI R Series expansion chassis Connect an NI R Series expansion chassis to the NI PXI FPGA card using a SHC68 68 RDIO cable Note NI Powertrain Control modules are not compatible with the National Instruments CompactDAQ chassis You can use NI Powertrain Control modules with NI cR...

Page 4: ...mum switching frequency or the output load the power supply begins to drop in voltage until it completely turns off or the overcurrent condition is removed When the NI 9754 is in this state it can accept new output state data Overvoltage Protection The TTL outputs of the NI 9754 are temporarily protected from 30 V one channel at a time Continued exposure to overvoltage conditions will degrade the ...

Page 5: ...emissions Industrial immunity EN 55011 CISPR 11 Group 1 Class A emissions AS NZS CISPR 11 Group 1 Class A emissions FCC 47 CFR Part 15B Class A emissions ICES 001 Class A emissions Caution When operating this product use shielded cables and accessories CE Compliance This product meets the essential requirements of applicable European Directives as follows 2006 95 EC Low Voltage Directive safety 20...

Page 6: ...er import export data Waste Electrical and Electronic Equipment WEEE EU Customers At the end of the product life cycle all products must be sent to a WEEE recycling center For more information about WEEE recycling centers National Instruments WEEE initiatives and compliance with WEEE Directive 2002 96 EC on Waste and Electronic Equipment visit ni com environment weee Battery Replacement and Dispos...

Reviews: