![National Instruments NI 9505E Operating Instructions And Specifications Download Page 25](http://html1.mh-extra.com/html/national-instruments/ni-9505e/ni-9505e_operating-instructions-and-specifications_3449846025.webp)
NI 9505E Operating Instructions and Specifications
24
ni.com
PWM
Rate............................................. 20 kHz recommended,
40 kHz max
Caution
Violating minimum pulse width will result
in unpredictable performance.
Minimum pulse width
(high or low)............................... 2
µ
s
Drive direction update rate ............... Nominally 20
µ
s
Current loop
ADC resolution .......................... 12 bits
Current range.............................. ±12.7 A
Maximum update rate................. 20
µ
s
Minimum inductance ........................ 500
µ
H
MTBF ............................................... 821,178 hours at 25 ºC;
Bellcore Issue 2, Method 1,
Case 3, Limited Part Stress
Method