DO0
DO1
DO2
DO3
DO4
DO5
DO6
DO7
Vsup
COM
0
1
2
3
4
5
6
7
8
9
DO0
DO1
DO2
DO3
DO4
DO5
DO6
DO7
Vsup
COM
0
1
2
3
4
5
6
7
8
9
Note
You must use 2-wire ferrules to create a secure connection when
connecting more than one wire to a single terminal on the NI-9474 with
screw terminal or NI-9474 with spring terminal.
Signal
Description
COM
Common reference connection to isolated ground
DO
Digital output signal connection
V
sup
Voltage supply connection
Table 1. NI-9474 Signal Descriptions
LED Pattern
Indication
Solid
The channel has been programmed to be in the ON state.
Off
The channel has been programmed to be in the OFF state.
Table 2. LED Indicators
Connecting Digital Devices
You can connect a variety of industrial devices, such as solenoids, motors, actuators,
relays, and lamps to the NI-9474. You must connect an external power supply to the
NI-9474. The power supply provides the current for the output channels.
Figure 1. Connecting an Industrial Device to the NI-9474
ni.com
8
NI-9474 Getting Started