impédances de boucle, des surtensions temporaires et des surtensions

transitoires dans le système doit être effectuée avant de procéder à des

mesures.

Measurement Category I is for measurements performed on circuits not directly

connected to the electrical distribution system referred to as MAINS voltage. MAINS

is a hazardous live electrical supply system that powers equipment. This category is

for measurements of voltages from specially protected secondary circuits. Such

voltage measurements include signal levels, special equipment, limited-energy

parts of equipment, circuits powered by regulated low-voltage sources, and

electronics.

Note

 Measurement Categories CAT I and CAT O are equivalent. These test

and measurement circuits are for other circuits not intended for direct

connection to the MAINS building installations of Measurement Categories

CAT II, CAT III, or CAT IV.

Safety Guidelines for Hazardous Voltages

Caution

 Ensure that hazardous voltage wiring is performed only by

qualified personnel adhering to local electrical standards.

Caution

 Do not mix hazardous voltage circuits and human-accessible

circuits on the same module.

Caution

 Ensure that devices and circuits connected to the module are

properly insulated from human contact.

Caution

 When module terminals are hazardous voltage LIVE (>42.4 V

pk

/60

V DC), you must ensure that devices and circuits connected to the module

are properly insulated from human contact.

© National Instruments

5

NI-9426 Getting Started

Summary of Contents for NI 9426

Page 1: ...NI 9426 Getting Started 2022 07 06...

Page 2: ...ous Voltages 5 Safety Guidelines for Hazardous Locations 5 Electromagnetic Compatibility Guidelines 7 Special Conditions for Marine Applications 7 Preparing the Environment 8 NI 9426 Pinout 8 Connecti...

Page 3: ...on Attention Suivez toutes les instructions et respectez toutes les mises en garde de la documentation d utilisation L utilisation du produit de toute autre fa on que celle sp cifi e risque de l endom...

Page 4: ...the transient overvoltage rating without breakdown or damage to the insulation An analysis of the working voltages loop impedances temporary overvoltages and transient overvoltages in the system must...

Page 5: ...e Measurement Categories CAT I and CAT O are equivalent These test and measurement circuits are for other circuits not intended for direct connection to the MAINS building installations of Measurement...

Page 6: ...aution Substitution of components may impair suitability for Class I Division 2 or Zone 2 Caution The system must be installed in an enclosure certified for the intended hazardous classified location...

Page 7: ...ated in the product specifications These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic env...

Page 8: ...output ports In addition take precautions when designing selecting and installing measurement probes and cables to ensure that the desired EMC performance is attained Preparing the Environment Ensure...

Page 9: ...t signal connection NC No connection Vsup Voltage supply connection Table 1 Signal Descriptions Connecting a Sinking Output Device You can connect 2 and 3 wire sinking output devices to the NI 9426 NI...

Page 10: ...earn about NI service offerings such as calibration options repair and replacement Visit ni com register to register your NI product Product registration facilitates technical support and ensures that...