Connecting Phase Measurements
You can connect three-phase measurement configurations and single-phase
measurement configurations to the NI 9246.
You can connect a current source to the NI 9246 for single-phase measurements. For
grounded current sources, connect to the chassis ground.
Figure 5. Connecting a Grounded or Floating Current Source
NI 9246
AI–
AI+
For three-phase measurements, connect three current sources to the NI 9246.
High-Vibration Applications
Proper strain relief of 5.26 mm
2
(10 AWG) cable is required to meet the shock and
vibration performance specifications stated in the NI 9246 Datasheet on
. Strain relieve all cabling as close to the chassis mounting plate as possible
to reduce the stresses exerted on the module. Ensure that you do not directionally
bias the module when applying strain relief.