1.
Align the NI 9149 and the panel mounting plate.
2.
Fasten the panel mounting plate to the NI 9149 using the screwdriver and M5 or number
10 screws. NI provides these screws with the panel mounting kit. Tighten the screws to a
maximum torque of 1.3 N · m (11.5 lb · in.).
Note
You must use the screws provided with the NI panel mounting kit
because they are the correct depth and thread for the panel mounting plate.
3.
Fasten the panel mounting plate to the surface using the screwdriver and screws that are
appropriate for the surface. The maximum screw size is M5 or number 10.
Panel Mounting Dimensions
The following figure shows the panel mounting dimensions for the NI 9149.
Figure 13.
NI 9149 Panel Mounting Dimensions
355.6 mm
(14.00 in.)
336.5 mm
(13.25 in.)
9.5 mm
(0.38 in.)
17.6 mm
(0.69 in.)
88.1 mm
(3.47 in.)
31.7 mm
(1.25 in.)
63.5 mm
(2.50 in.)
7.2 mm
(0.29 in.)
Mounting the Device on a DIN Rail
You can use the NI DIN rail mounting kit to mount the NI 9149 on a standard 35-mm DIN
rail.
16
|
ni.com
|
NI 9149 User Manual