National Instruments Corporation
25
SCC Quick Start Guide
5.
In the J21 drop-down list next to Power, select the correct
SC-2345/2350 power configuration. The SC-2345/2350 shielded
carrier has one of the following power modules factory-installed in
socket J21:
•
SCC-PWR01—5 VDC from the DAQ device or an external
supply
•
SCC-PWR02—Universal AC external supply
•
SCC-PWR03—7 to 42 VDC external supply module (power
supply not included)
For more information about how to select the power option for the
SCC 2345/2350 carrier module, refer to the
SC-2345/2350 User
Manual
.
6.
For each SCC module physically installed in the SC-2345/2350
carrier, add a corresponding entry in the SC-2345/2350 configuration
window. To add the SCC, click the Socket drop-down list and select the
correct module.
7.
If the module name does not appear in the list, either the module is not
allowed in that location or you do not have the current version of
NI-DAQ. If you do not have the current version of NI-DAQ, download
it from
ni.com/downloads
.
8.
Click
OK
after completing all SCC entries to finish the configuration
process.
For more information, refer to the
SC-2345/2350 User Manual
.
SC-2350: Configure TEDS
If you are using a TEDS sensor, complete the following steps to configure
the TEDS sensor in MAX:
1.
If MAX is not already open, double-click the MAX icon.
2.
Under NI-DAQmx Devices, right-click
SC-2350
and select
Properties
. The SC-2350 Configuration window opens. Leave the
DAQ Device, the SCC Connector Block ID, and where applicable, the
Cabled Device Connector as the defaults.
3.
Select the SCC module from the appropriate drop-down list (J
x
).
4.
The LED to the right of your module should appear bright green if your
sensor is connected. If the LED is not bright green, connect your sensor
now and click
Scan for TEDS
. Click
OK
.
5.
Expand the SC-2350 and the module connected to the TEDS sensor.
6.
Click the TEDS sensor, and the TEDS sensor specifications appear in
the right pane of the window.
7.
Verify that your TEDS data has imported correctly. If your data has not
imported correctly, repeat steps 2 through 7.