National Instruments IC-3173 Getting Started Manual Download Page 2

specified in the installation instructions. All covers and filler panels must be installed while
operating the device.

This is a Pollution Degree 2 device. Do not operate the device in an explosive atmosphere or
where flammable gases or fumes may be present. Operate the device only at or below the
pollution degree stated in the specifications. Pollution consists of any foreign matter—solid,
liquid, or gas—that may reduce dielectric strength or surface resistivity. The following is a
description of pollution degrees.

Pollution Degree 1—No pollution or only dry, nonconductive pollution occurs. The
pollution has no effect.

Pollution Degree 2—Normally only nonconductive pollution occurs. Occasionally,
nonconductive pollution becomes conductive because of condensation.

Pollution Degree 3—Conductive pollution or dry, nonconductive pollution occurs.
Nonconductive pollution becomes conductive because of condensation.

Clean the device and accessories by brushing off light dust with a soft, nonmetallic brush.
Remove other contaminants with a stiff, nonmetallic brush. The unit must be completely dry
and free from contaminants before returning it to service.

You must insulate signal connections for the maximum voltage for which the device is rated.
Do not exceed the maximum ratings for the device. Remove power from signal lines before
connection to or disconnection from the device.

Electromagnetic Compatibility Guidelines

This product was tested and complies with the regulatory requirements and limits for
electromagnetic compatibility (EMC) as stated in the product specifications. These
requirements and limits are designed to provide reasonable protection against harmful
interference when the product is operated in its intended operational electromagnetic
environment.

This product is intended for use in industrial locations. There is no guarantee that harmful
interference will not occur in a particular installation, when the product is connected to a test
object, or if the product is used in residential areas. To minimize the potential for the product
to cause interference to radio and television reception or to experience unacceptable
performance degradation, install and use this product in strict accordance with the instructions
in the product documentation.

Furthermore, any changes or modifications to the product not expressly approved by National
Instruments could void your authority to operate it under your local regulatory rules.

Caution

 

To ensure the specified EMC performance, operate this product only with

shielded cables and accessories.

2

  | 

ni.com

  | 

IC-3173 Getting Started Guide

Summary of Contents for IC-3173

Page 1: ...ortant safety information you must follow when installing and operating the device Do not operate the device in a manner not specified in the documentation Misuse of the device may result in a hazard...

Page 2: ...imum voltage for which the device is rated Do not exceed the maximum ratings for the device Remove power from signal lines before connection to or disconnection from the device Electromagnetic Compati...

Page 3: ...tion To ensure the specified EMC performance product installation requires either special considerations or user installed add on devices See the product installation instructions for further informat...

Page 4: ...r Accessible Battery Compartment not pictured 12 RS 232 RS 485 Serial Port 13 USB 3 0 Ports 14 Primary Gigabit Ethernet Port 15 Retention Mounts for USB 3 0 Ports 16 Retention Mounts for USB 2 0 Ports...

Page 5: ...tion The C terminals are internally connected to each other 6 Install the power connector into SYS PWR IN on the front panel of the controller and tighten the connector screw flanges to 0 3 to 0 4 N m...

Page 6: ...f the power connector plug and tighten the terminal screw to 0 2 to 0 25 N m 1 8 to 2 2 lb in of torque 5 Connect the negative lead of the isolated outputs power source to the C terminal of the power...

Page 7: ...male to pigtail cable part number 156083 03 for 3 meter cable 44 pin D SUB male to 44 position D SUB female cable part number 156084 03 for 3 meter cable or part number 156084 0R5 for 0 5 meter cable...

Page 8: ...r network device on the same network as the development computer 4 Verify the ACTIVITY LINK LED on the port is on or blinking The device negotiates an IP address when connected to a network with a DHC...

Page 9: ...tware set a Expand the IC 3173 under Remote Systems b Click the Software item below the IC 3173 in the configuration tree c Click Add Remove Software on the NI MAX toolbar to launch the LabVIEW Real T...

Page 10: ...words If you forget the password you must contact NI and reformat the controller Troubleshooting The IC 3173 Does Not Appear in MAX The IC 3173 may not be powered Verify that there is system power to...

Page 11: ...f you are having difficulty detecting the system and setting up the IC 3173 on your network you must configure the firewall to open the TCP UDP ports used by the IC 3173 and the host machine Refer to...

Page 12: ...ontroller either booted into an unsupported operating system was interrupted during the boot process or detected an unrecoverable software error Continuous blink red This indicates a hardware error An...

Page 13: ...declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification If...

Page 14: ...party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain rel...

Reviews: