background image

GETTING STARTED GUIDE

NI PXIe-7975R

NI FlexRIO

 FPGA Module for PXI Express

This document explains how to install your NI FlexRIO system, comprised of the
NI PXIe-7975R (NI 7975R) FlexRIO FPGA module and an NI FlexRIO adapter module.

For information about the device specifications, refer to the 

NI PXIe-7975R Specifications

,

available at 

Start

»

All Programs

»

National Instruments

»

NI FlexRIO

, and at 

ni.com/

manuals

.

For detailed information about the features and configuration options specific to the
NI FlexRIO FPGA module, refer to the 

NI FlexRIO Help

, available at 

Start

»

All Programs

»

National Instruments

»

NI FlexRIO

, and at 

ni.com/manuals

.

Contents

How to Use Your NI FlexRIO Documentation Set...................................................................2
Required Components...............................................................................................................3
Installing the Application Software and Driver........................................................................ 5
Installing the NI FlexRIO Devices............................................................................................6

Unpacking......................................................................................................................... 6
Preparing the Environment............................................................................................... 6
Installing the NI FlexRIO FPGA Module.........................................................................7
Confirming that Measurement & Automation Explorer (MAX) Recognizes the

Device......................................................................................................................... 8

Installing the NI FlexRIO Adapter Module...................................................................... 9

Installing PXI EMC Filler Panels........................................................................................... 10
NI FlexRIO FPGA Module Signals........................................................................................ 10
Compliance and Certifications................................................................................................12

Safety.............................................................................................................................. 12
Electromagnetic Compatibility....................................................................................... 12
CE Compliance .............................................................................................................. 12
Online Product Certification........................................................................................... 13
Environmental Management........................................................................................... 13

Electromagnetic Compatibility Guidelines.............................................................................13
Worldwide Support and Services............................................................................................ 14

Summary of Contents for FlexRIO PXIe-7975R

Page 1: ...ailable at Start All Programs National Instruments NI FlexRIO and at ni com manuals Contents How to Use Your NI FlexRIO Documentation Set 2 Required Components 3 Installing the Application Software and Driver 5 Installing the NI FlexRIO Devices 6 Unpacking 6 Preparing the Environment 6 Installing the NI FlexRIO FPGA Module 7 Confirming that Measurement Automation Explorer MAX Recognizes the Device...

Page 2: ...ion Getting started guide for your FPGA module Available from the Start menu and at ni com manuals Contains installation instructions for your NI FlexRIO system Specifications document for your FPGA module Available from the Start menu and at ni com manuals Contains specifications for your NI 7975R module Getting started guide for your adapter module Available from the Start menu and at ni com man...

Page 3: ...EW FPGA functions and intellectual property to share NI FlexRIO product page ni com flexrio Contains product information and data sheets for NI FlexRIO devices Required Components The following items are necessary to set up and use your NI FlexRIO system The NI FlexRIO hardware device comprised of the following items NI 7975R NI FlexRIO adapter module Note You can use the NI FlexRIO FPGA module wi...

Page 4: ...dapter Module Support is available at ni com downloads Search for flexrio adapter module support to download the latest version of NI FlexRIO Adapter Module Support You do not need this software if you are not using an adapter module Optional LabVIEW Real Time Module A PXI Express CompactPCI Express chassis One of the following controllers PXI Express CompactPCI Express embedded controller MXI kit...

Page 5: ...bVIEW FPGA Module Refer to the LabVIEW FPGA Module Release and Upgrade Notes for installation instructions and information about getting started with the LabVIEW FPGA Module Documentation for the LabVIEW FPGA Module is available at ni com manuals and by selecting Start All Programs National Instruments LabVIEW LabVIEW Manuals 3 Optional Install the LabVIEW Real Time Module Refer to the LabVIEW Rea...

Page 6: ... steps 1 Touch the antistatic package to a metal part of the computer chassis before removing the module from the package Caution Never touch the exposed pins of connectors 2 Remove each module from the package and inspect it for loose components or any other sign of damage Notify NI if the modules appear damaged in any way Do not install a damaged module into the chassis Preparing the Environment...

Page 7: ... 1062Q 1 2 3 4 5 1 PXI Express System Controller Slot 2 PXI Peripheral Slot 3 PXI Express Hybrid Peripheral Slot 4 PXI Express System Timing Slot 5 PXI Express Peripheral Slot Refer to the chassis documentation for specifications 3 Remove the filler panel of an unused PXI Express slot 4 Touch any metal part of the chassis to discharge any static electricity Place the PXI Express module edges into ...

Page 8: ...n page 5 Confirming that Measurement Automation Explorer MAX Recognizes the Device Use Measurement Automation Explorer MAX to configure your National Instruments hardware MAX informs other programs about which devices reside in the system and how they are configured MAX is automatically installed with NI FlexRIO Support 1 Launch MAX by navigating to Start All Programs National Instruments NI MAX o...

Page 9: ...I FlexRIO FPGA module as shown in the figure below Figure 5 Installing the NI FlexRIO Adapter Module PXI 1000B 1 4 3 2 5 1 NI FlexRIO Adapter Module 2 Captive Screw 3 Guide Pin 4 PXI PXI Express Chassis 5 NI FlexRIO FPGA Module The connection may be tight but do not force the adapter module into place 2 Tighten the captive screws on the NI FlexRIO adapter module to secure it to the NI FlexRIO FPGA...

Page 10: ...he PXI EMC filler panel Figure 6 PXI EMC Filler Panels and Chassis 1 1 3 2 1 Captive Screw Covers 2 Captive Mounting Screws 3 EMC Gasket Note You must populate all slots with a module or a PXI EMC filler panel to ensure proper module cooling Do not over tighten screws 2 5 lb in maximum For additional information about the use of PXI EMC filler panels in your PXI system visit ni com info and enter ...

Page 11: ..._n GPIO_16 GND GPIO_17_n GPIO_17 GND GPIO_18_n GPIO_18 GND GPIO_19_n GPIO_19 GND GPIO_20_n GPIO_20 GND GPIO_21_n GPIO_21 GND GPIO_22_n GPIO_22 GND GPIO_23_n GPIO_23 GND GPIO_58_n GPIO_58 GND GPIO_59_n GPIO_59 GND GPIO_CC_60_n GPIO_CC_60 GND GPIO_61_n GPIO_61 GND GPIO_62_n GPIO_62 GND GPIO_63_n GPIO_63 GND GND GPIO_64_n GPIO_64 GPIO_65_n GPIO_65 GND GPIO_66_n GPIO_67_n GPIO_66 GND GND GPIO_67 G20 G...

Page 12: ...ass A emissions FCC 47 CFR Part 15B Class A emissions ICES 001 Class A emissions Note In the United States per FCC 47 CFR Class A equipment is intended for use in commercial light industrial and heavy industrial locations In Europe Canada Australia and New Zealand per CISPR 11 Class A equipment is intended for use only in heavy industrial locations Note Group 1 equipment per CISPR 11 is any indust...

Page 13: ...电子信息产品污染控制管理办法 中国 RoHS 中国客户 National Instruments 符合中国电子信息产品中限制使用某些有害物 质指令 RoHS 关于 National Instruments 中国 RoHS 合规性信息 请登录 ni com environment rohs_china For information about China RoHS compliance go to ni com environment rohs_china Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility EMC stated in...

Page 14: ... and phone assistance from NI Application Engineers Visit ni com services for NI Factory Installation Services repairs extended warranty and other services Visit ni com register to register your National Instruments product Product registration facilitates technical support and ensures that you receive important information updates from NI A Declaration of Conformity DoC is our claim of compliance...

Page 15: ...nd third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export data NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FO...