INSTALLATION GUIDE

F

IELD

P

OINT

 B

US

 E

XTENDER

 C

ABLE

If you have space constraints, you can use the FieldPoint Bus Extender Cable to mount a 
FieldPoint bank in two or three rows. 

Caution

You should not use more than two FieldPoint Bus Extender Cables per 

FieldPoint bank.

Caution

Disconnect power from the network module and terminal bases before 

you install the Bus Extender Cable. Do not disconnect a Bus Extender Cable 
while the FieldPoint bank is powered on.

Choosing a Configuration

Before you begin installing the Bus Extender Cable, choose a configuration for the 
FieldPoint bank. With the Bus Extender Cable, you can mount rows of modules with 
terminal blocks together (bottom-to-bottom) or with terminal blocks apart (top-to-top). 
Mounting modules with terminal blocks together lets you use one wiring conduit for 
two rows of modules and is the recommended method due to cooling considerations. 
You should install higher-powered I/O modules on top in this configuration to further help 
with cooling. Figure 1 shows configuration examples with two rows. You can use up to 
three rows.

Figure 1.  

FieldPoint Bank Configuration Options

Terminal Blocks Together

Terminal Blocks Apart

network module

I/O modules

more I/O modules

more I/O modules

network module

I/O modules

(Recommended due to better cooling)

Summary of Contents for FieldPoint

Page 1: ...erminal bases before you install the Bus Extender Cable Do not disconnect a Bus Extender Cable while the FieldPoint bank is powered on Choosing a Configuration Before you begin installing the Bus Extender Cable choose a configuration for the FieldPoint bank With the Bus Extender Cable you can mount rows of modules with terminal blocks together bottom to bottom or with terminal blocks apart top to ...

Page 2: ...blocks together Dimensions are given in inches millimeters Figure 2 Mounting with Terminal Blocks Together 6 70 170 max 14 0 355 max 1 11 28 2 1 76 44 6 1 23 31 2 1 23 31 2 1 05 26 7 female end male end Cable Mounting Holes Other Terminal Bases if installed Other Terminal Bases if installed and network module 0 59 14 9 ...

Page 3: ...el is the more secure installation option and may prevent accidental disconnection Installing the Bus Extender Cable on a DIN Rail Follow these steps to install the Bus Extender Cable on a DIN rail 1 Install the FieldPoint bank on the DIN rail Refer to the Quick Start Guide for the network module you are using 2 Make sure power is disconnected from the FieldPoint bank 2 00 50 8 max 9 30 236 max 1 ...

Page 4: ...et on the DIN rail and slide it under the mounting tab of the Bus Extender Cable 5 Drive the long screw that came with the DIN rail mounting kit through the mounting tab of the Bus Extender Cable and the mounting bracket Drive the short screw that came with the DIN rail mounting kit through the other end of the mounting bracket and use the split lock washer The maximum tightening torque for each s...

Page 5: ...r Cable on a DIN Rail with a Metal Spacer Installing the Bus Extender Cable on a Panel Follow these steps to install the Bus Extender Cable on a panel 1 Drill pilot holes into the panel according to the dimensions in Figure 2 or 3 2 Install the FieldPoint bank on the panel Refer to the Quick Start Guide for the network module you are using 3 Make sure power is disconnected from the FieldPoint bank...

Page 6: ...t holes you drilled on the panel The Bus Extender Cable installed on a panel should appear as shown in Figure 6 Figure 6 Installing the Bus Extender Cable on a Panel Powering Up the FieldPoint Bank You can now connect power to the FieldPoint bank Remember to disconnect power first if you need to remove the Bus Extender Cable at a later time 1 Short spacer 1 ...